Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2011 |
Principal Product | Multi-wall bags |
NAICS | 322220 - Paper Bag and Coated and Treated Paper Manufacturing |
SIC | 2674 - Bags: Uncoated Paper & Multiwall |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 24,000 Tons |
Production Hrs. Annual | 8,568 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $298,190 | 5,324,822 | kWh | $0.06 |
Electricity Demand | $169,213 | 10,716 | kW-months/year | $15.79 |
Electricity Fees | $29,400 | - | $ | - |
Natural Gas | $91,242 | 9,041 | MMBtu | $10.09 |
TOTAL ENERGY COSTS | $596,981 | |||
RECOMMENDED SAVINGS* | $115,217 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $85,057 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $30,160 Cost: $2,400 |
- | - | - | - | - | - | $30,160 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$30,160 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4155 METER WASTE WATER |
Savings: $5,529 Cost: $2,500 |
- | - | - | - | $5,529 | 2,373,000 | - | - |
- - kWh |
- - kW-months/year |
$5,529 2,373,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $3,617 Cost: $9,994 |
$1,826 | 31,110 | $1,791 | 93 | - | - | - | - |
$1,826 31,110 kWh |
$1,791 93 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $51,129 Cost: $25,000 |
$34,072 | 580,440 | $17,057 | 890 | - | - | - | - |
$34,072 580,440 kWh |
$17,057 890 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $24,782 Cost: $14,000 |
$13,888 | 236,590 | $10,894 | 569 | - | - | - | - |
$13,888 236,590 kWh |
$10,894 569 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $115,217 Cost: $53,894 |
$49,786 | 848,140 | $29,742 | 1,553 | $5,529 | 2,373,000 | $30,160 | - | $49,786 848,140 kWh |
$29,742 1,553 kW-months/year |
$5,529 2,373,000 Tgal |
$30,160 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $85,057 Cost: $51,494 |
$49,786 | 848,140 | $29,742 | 1,553 | $5,529 | 2,373,000 | - | - | $49,786 848,140 kWh |
$29,742 1,553 kW-months/year |
$5,529 2,373,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes |