IAC logo
IAC Assessment: GT0976
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: GT0976
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2024
Principal Product Commercial Refrigeration
NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585 - Refrigeration And Heating Equipment
Sales $100,000,000-$500,000,000
# of Employees 509
Plant Area (Sq.Ft.) 247,000
Annual Production 175,000 Units
Production Hrs. Annual 4,680
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $918,515 11,956,959 kWh $0.08
Natural Gas $27,262 4,105 MMBtu $6.64
TOTAL ENERGY COSTS $945,777
RECOMMENDED SAVINGS* $331,827 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Fees Electricity Usage Electricity Fees
$ kWh $ $
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$12,289
Cost:
$800
$12,289 159,607 - - $12,289
159,607
kWh
-
-
$
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$20,852
Cost:
$2,185
$20,852 270,816 - - $20,852
270,816
kWh
-
-
$
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$375
Cost:
$200
$375 4,879 - - $375
4,879
kWh
-
-
$
04: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$20,799
Cost:
$15,000
$20,799 269,852 - - $20,799
269,852
kWh
-
-
$
05: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$4,240
Cost:
$13,403
- - $4,240 - -
-
kWh
$4,240
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$273,272
Cost:
$5,081,734
$273,272 3,557,380 - - $273,272
3,557,380
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$331,827
Cost:
$5,113,322
$327,587 4,262,534 $4,240 - $327,587
4,262,534
kWh
$4,240
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Electricity Fees Electricity Usage Electricity Fees