IAC logo
IAC Assessment: GT0982
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: GT0982
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2024
Principal Product Forklift Material Handling Attachments
NAICS 333924 - Industrial Truck, Tractor, Trailer, and Stacker Machinery Manufacturing
SIC 3537 - Industrial Trucks And Tractors
Sales $50,000,000-$100,000,000
# of Employees 100
Plant Area (Sq.Ft.) 62,000
Annual Production 117,645 Units
Production Hrs. Annual 4,160
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $189,089 1,905,400 kWh $0.10
Natural Gas $1,844 134 MMBtu $13.76
TOTAL ENERGY COSTS $190,933
RECOMMENDED SAVINGS* $97,661 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Personnel Changes Electricity Usage Personnel Changes
$ kWh $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$19,510
Cost:
$1,850
$22,410 226,368 $(-2,900) - $22,410
226,368
kWh
$(-2,900)
-
$
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$2,144
Cost:
$1,200
$2,144 21,653 - - $2,144
21,653
kWh
-
-
$
03: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$194
Cost:
$135
$194 1,961 - - $194
1,961
kWh
-
-
$
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,571
Cost:
$1,100
$1,571 15,866 - - $1,571
15,866
kWh
-
-
$
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$923
Cost:
$800
$923 9,328 - - $923
9,328
kWh
-
-
$
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$5,851
Cost:
$12,950
$5,851 59,099 - - $5,851
59,099
kWh
-
-
$
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$67,468
Cost:
$877,960
$67,468 679,858 - - $67,468
679,858
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$97,661
Cost:
$895,995
$100,561 1,014,133 $(-2,900) - $100,561
1,014,133
kWh
$(-2,900)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Personnel Changes Electricity Usage Personnel Changes