Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1999 |
Principal Product | Hermetic Seals |
NAICS | n/a |
SIC | 3679 - Electronic Components, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 33,000 |
Annual Production | 20,000 Pounds |
Production Hrs. Annual | 3,050 |
Location (State) | CT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $95,666 | 1,061,841 | kWh | $0.09 |
Electricity Demand | $39,197 | 5,200 | kW-months/year | $7.54 |
Electricity Fees | $(-8,121) | - | $ | - |
Natural Gas | $26,296 | 4,098 | MMBtu | $6.42 |
TOTAL ENERGY COSTS | $153,038 | |||
RECOMMENDED SAVINGS* | $57,459 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,800 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,313 Cost: $1,600 |
$1,313 | 14,654 | - | - | - | - | - | - |
$1,313 14,654 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $723 Cost: $1,500 |
$544 | 6,155 | $179 | 24 | - | - | - | - |
$544 6,155 kWh |
$179 24 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,454 Cost: $3,900 |
$3,454 | 38,394 | - | - | - | - | - | - |
$3,454 38,394 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT |
Savings: $9,653 Cost: - |
$9,653 | 107,268 | - | - | - | - | - | - |
$9,653 107,268 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,927 Cost: $2,160 |
$1,927 | 21,395 | - | - | - | - | - | - |
$1,927 21,395 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2514 COVER OPEN TANKS |
Savings: $3,955 Cost: $4,450 |
- | - | - | - | $3,955 | 616 | - | - |
- - kWh |
- - kW-months/year |
$3,955 616 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.632 CHANGE OPERATING CONDITIONS |
Savings: $7,654 Cost: $20,000 |
- | - | - | - | - | - | $7,654 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$7,654 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $1,980 Cost: $1,030 |
- | - | - | - | - | - | $1,980 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,980 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,800 Cost: $120 |
- | - | - | - | - | - | $1,800 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $25,000 Cost: $800 |
- | - | - | - | - | - | $25,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$25,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $57,459 Cost: $35,560 |
$16,891 | 187,866 | $179 | 24 | $3,955 | 616 | $36,434 | - | $16,891 187,866 kWh |
$179 24 kW-months/year |
$3,955 616 MMBtu |
$36,434 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,800 Cost: $120 |
- | - | - | - | - | - | $1,800 | - | - - kWh |
- - kW-months/year |
- - MMBtu |
$1,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||