IAC logo
IAC Assessment: IA0425
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IA0425
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Iowa State University
Assessment Year 2008
Principal Product Cotton harvesters
NAICS 333111 - Farm Machinery and Equipment Manufacturing
SIC 3523 - Farm Machinery And Equipment
Sales >$500,000,000
# of Employees 1,166
Plant Area (Sq.Ft.) 586,577
Annual Production 70,442 Tons
Production Hrs. Annual 6,000
Location (State) IA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,209,591 52,887,135 kWh $0.04
Natural Gas $3,836,525 410,364 MMBtu $9.35
TOTAL ENERGY COSTS $6,046,116
RECOMMENDED SAVINGS* $80,342 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $73,970
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$1,843
Cost:
$600
- - - - $1,843 201 -
-
kWh
-
-
kW-months/year
$1,843
201
MMBtu
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,124
Cost:
$640
- - - - $1,124 122 -
-
kWh
-
-
kW-months/year
$1,124
122
MMBtu
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$15,476
Cost:
$600
- - - - $15,476 1,684 -
-
kWh
-
-
kW-months/year
$15,476
1,684
MMBtu
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$50,635
Cost:
$291,629
- - - - $50,635 5,513 -
-
kWh
-
-
kW-months/year
$50,635
5,513
MMBtu
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$3,405
Cost:
$6,450
$3,405 186,384 - - - - $3,405
186,384
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$7,859
Cost:
$2,000
$5,442 297,840 $2,417 34 - - $5,442
297,840
kWh
$2,417
34
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$80,342
Cost:
$301,919
$8,847 484,224 $2,417 34 $69,078 7,520 $8,847
484,224
kWh
$2,417
34
kW-months/year
$69,078
7,520
MMBtu
TOTAL IMPLEMENTED Savings:
$73,970
Cost:
$294,229
$5,442 297,840 $2,417 34 $66,111 7,197 $5,442
297,840
kWh
$2,417
34
kW-months/year
$66,111
7,197
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas