Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2023 |
Principal Product | Office Space |
NAICS | 551114 - Corporate, Subsidiary, and Regional Managing Offices |
SIC | 6541 - Title Abstract Offices |
Sales | <$500,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 40,560 |
Annual Production | 1 Units |
Production Hrs. Annual | 2,574 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $42,618 | 463,200 | kWh | $0.09 |
Electricity Demand | $18,934 | 1,493 | kW-months/year | $12.68 |
Electricity Fees | $8,982 | - | $ | - |
Natural Gas | $14,146 | 1,659 | MMBtu | $8.53 |
TOTAL ENERGY COSTS | $84,680 | |||
RECOMMENDED SAVINGS* | $69,808 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,190 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $24,563 Cost: $10,218 |
$14,953 | 162,535 | $9,610 | 758 | - | - |
$14,953 162,535 kWh |
$9,610 758 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $26,775 Cost: $203,319 |
$22,463 | 244,168 | $4,312 | 340 | - | - |
$22,463 244,168 kWh |
$4,312 340 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $5,835 Cost: - |
$3,552 | 38,610 | $2,283 | 180 | - | - |
$3,552 38,610 kWh |
$2,283 180 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $796 Cost: - |
- | - | - | - | $796 | 93 |
- - kWh |
- - kW-months/year |
$796 93 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7494 INSTALL STORM WINDOWS AND DOORS |
Savings: $619 Cost: $7,463 |
$50 | 542 | $85 | 7 | $485 | 57 |
$50 542 kWh |
$85 7 kW-months/year |
$485 57 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $306 Cost: $388 |
$184 | 2,005 | $121 | 10 | - | - |
$184 2,005 kWh |
$121 10 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $254 Cost: - |
$71 | 772 | $183 | 14 | - | - |
$71 772 kWh |
$183 14 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $4,154 Cost: $4,776 |
$3,826 | 41,586 | $328 | 25 | - | - |
$3,826 41,586 kWh |
$328 25 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,267 Cost: - |
$2,598 | 28,237 | $1,670 | 132 | - | - |
$2,598 28,237 kWh |
$1,670 132 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.1224 REPLACE BOILER |
Savings: $2,240 Cost: $49,894 |
- | - | - | - | $2,240 | 263 |
- - kWh |
- - kW-months/year |
$2,240 263 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $69,808 Cost: $276,058 |
$47,698 | 518,455 | $18,590 | 1,466 | $3,520 | 413 | $47,698 518,455 kWh |
$18,590 1,466 kW-months/year |
$3,520 413 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,190 Cost: $388 |
$3,808 | 41,387 | $2,587 | 204 | $796 | 93 | $3,808 41,387 kWh |
$2,587 204 kW-months/year |
$796 93 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |