Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Indiana University-Purdue University
Assessment Year 2013
Principal Product Lithium Ion Cells, Modules, Packs, Systems and Battery
NAICS 335912 - Primary Battery Manufacturing
SIC 3692 - Primary Batteries, Dry And Wet
Sales $10,000,000-$50,000,000
# of Employees 75
Plant Area (Sq.Ft.) 220,000
Annual Production 615 Pieces
Production Hrs. Annual 2,000
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $175,566 3,033,820 kWh $0.06
Electricity Demand $76,839 7,889 kW-months/year $9.74
Electricity Fees $4,681 - $ -
Natural Gas $87,202 11,553 MMBtu $7.55
TOTAL ENERGY COSTS $344,287
RECOMMENDED SAVINGS* $67,318 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $31,787
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$21,525
Cost:
-
$1,984 34,095 - - $19,541 2,588 $1,984
34,095
kWh
-
-
kW-months/year
$19,541
2,588
MMBtu
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$5,948
Cost:
-
$5,948 102,346 - - - - $5,948
102,346
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,627
Cost:
-
$1,325 22,776 $302 31 - - $1,325
22,776
kWh
$302
31
kW-months/year
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,371
Cost:
-
$1,371 23,568 - - - - $1,371
23,568
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,316
Cost:
$1,171
- - - - $1,316 174 -
-
kWh
-
-
kW-months/year
$1,316
174
MMBtu
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,095
Cost:
$4,480
$1,043 17,920 $1,052 108 - - $1,043
17,920
kWh
$1,052
108
kW-months/year
-
-
MMBtu
07: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING Savings:
$33,436
Cost:
$104,600
$21,861 375,691 $3,959 407 $7,616 1,009 $21,861
375,691
kWh
$3,959
407
kW-months/year
$7,616
1,009
MMBtu
TOTAL RECOMMENDED Savings:
$67,318
Cost:
$110,251
$33,532 576,396 $5,313 546 $28,473 3,771 $33,532
576,396
kWh
$5,313
546
kW-months/year
$28,473
3,771
MMBtu
TOTAL IMPLEMENTED Savings:
$31,787
Cost:
$1,171
$10,628 182,785 $302 31 $20,857 2,762 $10,628
182,785
kWh
$302
31
kW-months/year
$20,857
2,762
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas