IAC logo
IAC Assessment: KS2313
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KS2313
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Kennesaw State
Assessment Year 2023
Principal Product Tufted Broadloom Carpet
NAICS 314110 - Carpet and Rug Mills
SIC 2273 - Carpets And Rugs
Sales $100,000,000-$500,000,000
# of Employees 450
Plant Area (Sq.Ft.) 550,000
Annual Production 6,306,000 Units
Production Hrs. Annual 8,400
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,292,046 14,518,267 kWh $0.09
Natural Gas $545,538 62,451 MMBtu $8.74
TOTAL ENERGY COSTS $1,857,878
RECOMMENDED SAVINGS* $237,426 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $37,631
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$24,149
Cost:
$29,920
$24,149 271,341 - - - - $24,149
271,341
kWh
-
-
MMBtu
-
-
$
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,937
Cost:
$60
$1,937 21,765 - - - - $1,937
21,765
kWh
-
-
MMBtu
-
-
$
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$28,388
Cost:
$6,340
- - $28,388 3,248 - - -
-
kWh
$28,388
3,248
MMBtu
-
-
$
04: 2.8112 COMBINE UTILITY METERS Savings:
$11,545
Cost:
$33,000
- - - - $11,545 - -
-
kWh
-
-
MMBtu
$11,545
-
$
05: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT Savings:
$106,263
Cost:
$627,000
$149,520 1,680,000 $(-36,857) (-4,217) $(-6,400) - $149,520
1,680,000
kWh
$(-36,857)
(-4,217)
MMBtu
$(-6,400)
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$65,144
Cost:
$514,950
$65,144 731,960 - - - - $65,144
731,960
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$237,426
Cost:
$1,211,270
$240,750 2,705,066 $(-8,469) (-969) $5,145 - $240,750
2,705,066
kWh
$(-8,469)
(-969)
MMBtu
$5,145
-
$
TOTAL IMPLEMENTED Savings:
$37,631
Cost:
$62,980
$26,086 293,106 - - $11,545 - $26,086
293,106
kWh
-
-
MMBtu
$11,545
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes