Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | Lehigh University |
---|---|
Assessment Year | 2002 |
Principal Product | Corrugated Cardboard Sheets |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 57 |
Plant Area (Sq.Ft.) | 116,640 |
Annual Production | 0 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $233,553 | 2,719,400 | kWh | $0.09 |
Electricity Demand | $87,607 | 6,063 | kW-months/year | $14.45 |
Natural Gas | $51,575 | 11,565 | MMBtu | $4.46 |
LPG | $17,658 | 1,528 | MMBtu | $11.56 |
Fuel Oil #6 | $158,912 | 32,768 | MMBtu | $4.85 |
TOTAL ENERGY COSTS | $549,305 | |||
RECOMMENDED SAVINGS* | $77,870 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #6 | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #6 | Water Consumption | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,384 Cost: $1,200 |
$1,465 | 29,950 | $919 | - | - | - | - | - | - | - | - | - |
$1,465 29,950 kWh |
$919 - kW-months/year |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $34,475 Cost: $17,000 |
- | - | - | - | $34,475 | 7,182 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$34,475 7,182 MMBtu |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $1,527 Cost: $2,000 |
- | - | - | - | - | - | - | - | $1,527 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$1,527 - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $34,222 Cost: $60,000 |
- | - | - | - | - | - | - | - | - | - | $34,222 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - Tgal |
$34,222 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,262 Cost: $1,000 |
- | - | - | - | $1,289 | 819 | $3,973 | 819 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,289 819 MMBtu |
$3,973 819 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $77,870 Cost: $81,200 |
$1,465 | 29,950 | $919 | - | $35,764 | 8,001 | $3,973 | 819 | $1,527 | - | $34,222 | - | $1,465 29,950 kWh |
$919 - kW-months/year |
$35,764 8,001 MMBtu |
$3,973 819 MMBtu |
$1,527 - Tgal |
$34,222 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #6 | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #6 | Water Consumption | Primary Product |