Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2011 |
Principal Product | Lass 80 Heavy Duty Trucks |
NAICS | 336120 - Heavy Duty Truck Manufacturing |
SIC | 3711 - Motor Vehicles And Car Bodies |
Sales | $50,000,000-$100,000,000 |
# of Employees | 107 |
Plant Area (Sq.Ft.) | 930,000 |
Annual Production | 11,800 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $767,104 | 11,218,000 | kWh | $0.07 |
Electricity Demand | $13,967 | 26,230 | kW-months/year | $0.53 |
Natural Gas | $643,875 | 70,486 | MMBtu | $9.13 |
TOTAL ENERGY COSTS | $1,424,946 | |||
RECOMMENDED SAVINGS* | $312,637 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $156,891 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $92,227 Cost: $175,000 |
$40,160 | 590,594 | $939 | 1,771 | $51,128 | 5,600 |
$40,160 590,594 kWh |
$939 1,771 kW-months/year |
$51,128 5,600 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1224 REPLACE BOILER |
Savings: $91,620 Cost: $240,000 |
- | - | - | - | $91,620 | 10,035 |
- - kWh |
- - kW-months/year |
$91,620 10,035 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $61,378 Cost: $125 |
$27,305 | 401,549 | - | - | $34,073 | 3,732 |
$27,305 401,549 kWh |
- - kW-months/year |
$34,073 3,732 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $42,335 Cost: $94,400 |
$41,404 | 608,880 | $931 | 1,753 | - | - |
$41,404 608,880 kWh |
$931 1,753 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $15,778 Cost: $2,102 |
$15,624 | 229,764 | $154 | 291 | - | - |
$15,624 229,764 kWh |
$154 291 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,653 Cost: $7,280 |
$5,653 | 83,121 | - | - | - | - |
$5,653 83,121 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,286 Cost: $1,900 |
$3,211 | 47,226 | $75 | 142 | - | - |
$3,211 47,226 kWh |
$75 142 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $360 Cost: $400 |
$350 | 5,144 | $10 | 18 | - | - |
$350 5,144 kWh |
$10 18 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $312,637 Cost: $521,207 |
$133,707 | 1,966,278 | $2,109 | 3,975 | $176,821 | 19,367 | $133,707 1,966,278 kWh |
$2,109 3,975 kW-months/year |
$176,821 19,367 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $156,891 Cost: $177,025 |
$70,676 | 1,039,369 | $1,014 | 1,913 | $85,201 | 9,332 | $70,676 1,039,369 kWh |
$1,014 1,913 kW-months/year |
$85,201 9,332 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |