Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2014 |
Principal Product | Rolls & English Miffins |
NAICS | 311812 - Commercial Bakeries |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 30,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $406,162 | 6,346,281 | kWh | $0.06 |
Electricity Demand | $39,201 | 11,022 | kW-months/year | $3.56 |
Electricity Fees | $22,441 | - | $ | - |
Natural Gas | $301,265 | 48,907 | MMBtu | $6.16 |
TOTAL ENERGY COSTS | $769,069 | |||
RECOMMENDED SAVINGS* | $126,109 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $45,016 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $15,425 Cost: $1,330 |
- | - | - | - | $15,425 | 2,504 |
- - kWh |
- - kW-months/year |
$15,425 2,504 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $10,341 Cost: $2,500 |
$9,599 | 149,978 | $742 | 208 | - | - |
$9,599 149,978 kWh |
$742 208 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $8,711 Cost: $3,192 |
$3,691 | 57,676 | $5,020 | 1,410 | - | - |
$3,691 57,676 kWh |
$5,020 1,410 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,614 Cost: $673 |
$1,465 | 22,883 | $149 | 42 | - | - |
$1,465 22,883 kWh |
$149 42 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $2,157 Cost: $1,170 |
- | - | - | - | $2,157 | 350 |
- - kWh |
- - kW-months/year |
$2,157 350 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $22,081 Cost: $10,500 |
$22,081 | 345,021 | - | - | - | - |
$22,081 345,021 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,223 Cost: $1,830 |
- | - | - | - | $2,223 | 361 |
- - kWh |
- - kW-months/year |
$2,223 361 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $13,345 Cost: $17,700 |
$12,398 | 193,723 | $947 | 266 | - | - |
$12,398 193,723 kWh |
$947 266 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,381 Cost: $11,736 |
$3,381 | 52,835 | - | - | - | - |
$3,381 52,835 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $42,779 Cost: $169,000 |
$39,742 | 620,975 | $3,037 | 853 | - | - |
$39,742 620,975 kWh |
$3,037 853 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $4,052 Cost: $20,066 |
$3,700 | 57,808 | $352 | 99 | - | - |
$3,700 57,808 kWh |
$352 99 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $126,109 Cost: $239,697 |
$96,057 | 1,500,900 | $10,247 | 2,878 | $19,805 | 3,215 | $96,057 1,500,900 kWh |
$10,247 2,878 kW-months/year |
$19,805 3,215 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $45,016 Cost: $61,172 |
$41,560 | 649,387 | $1,299 | 365 | $2,157 | 350 | $41,560 649,387 kWh |
$1,299 365 kW-months/year |
$2,157 350 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |