Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2019 |
Principal Product | Canned food products |
NAICS | 311421 - Fruit and Vegetable Canning |
SIC | 2033 - Canned Fruits And Vegetables |
Sales | $100,000,000-$500,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 522,720 |
Annual Production | 14,500,000 Units |
Production Hrs. Annual | 5,240 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $489,992 | 7,615,200 | kWh | $0.06 |
Electricity Demand | $41,346 | 16,234 | kW-months/year | $2.55 |
Electricity Fees | $12,132 | - | $ | - |
Natural Gas | $1,103,800 | 313,122 | MMBtu | $3.53 |
TOTAL ENERGY COSTS | $1,647,270 | |||
RECOMMENDED SAVINGS* | $639,375 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $159,828 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6122 ADJUST VENTS TO MINIMIZE ENERGY USE |
Savings: $43,794 Cost: - |
$(-5,729) | (-89,520) | $(-477) | (-187) | - | - | $50,000 | - |
$(-5,729) (-89,520) kWh |
$(-477) (-187) kW-months/year |
- - MMBtu |
$50,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $19,944 Cost: $1,143 |
- | - | - | - | $19,944 | 5,666 | - | - |
- - kWh |
- - kW-months/year |
$19,944 5,666 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $96,090 Cost: $12,000 |
$95,899 | 1,498,425 | $191 | 75 | - | - | - | - |
$95,899 1,498,425 kWh |
$191 75 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,802 Cost: $750 |
$2,802 | 43,788 | - | - | - | - | - | - |
$2,802 43,788 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $401,509 Cost: $120,000 |
- | - | - | - | $401,509 | 113,742 | - | - |
- - kWh |
- - kW-months/year |
$401,509 113,742 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.5125 SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE |
Savings: $14,597 Cost: $17,000 |
$13,513 | 211,144 | $1,084 | 425 | - | - | - | - |
$13,513 211,144 kWh |
$1,084 425 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $48,028 Cost: $55,800 |
- | - | - | - | $48,028 | 13,606 | - | - |
- - kWh |
- - kW-months/year |
$48,028 13,606 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $12,611 Cost: $28,000 |
$10,344 | 161,629 | $2,267 | 889 | - | - | - | - |
$10,344 161,629 kWh |
$2,267 889 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $639,375 Cost: $234,693 |
$116,829 | 1,825,466 | $3,065 | 1,202 | $469,481 | 133,014 | $50,000 | - | $116,829 1,825,466 kWh |
$3,065 1,202 kW-months/year |
$469,481 133,014 MMBtu |
$50,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $159,828 Cost: $13,143 |
$90,170 | 1,408,905 | $(-286) | (-112) | $19,944 | 5,666 | $50,000 | - | $90,170 1,408,905 kWh |
$(-286) (-112) kW-months/year |
$19,944 5,666 MMBtu |
$50,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |