Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2024 |
Principal Product | electronic connectors |
NAICS | 335931 - Current-Carrying Wiring Device Manufacturing |
SIC | 3678 - Electronic Connectors |
Sales | $100,000,000-$500,000,000 |
# of Employees | 239 |
Plant Area (Sq.Ft.) | 108,000 |
Annual Production | 310,433 Units |
Production Hrs. Annual | 4,212 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $344,582 | 6,248,000 | kWh | $0.06 |
Electricity Demand | $97,436 | 18,912 | kW-months/year | $5.15 |
Electricity Fees | $56,795 | - | $ | - |
Natural Gas | $18,544 | 1,784 | MMBtu | $10.39 |
TOTAL ENERGY COSTS | $517,357 | |||
RECOMMENDED SAVINGS* | $426,075 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $8,432 Cost: - |
$5,637 | 102,488 | - | - | $2,795 | 269 | - | - |
$5,637 102,488 kWh |
- - kW-months/year |
$2,795 269 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,203 Cost: - |
$2,467 | 44,863 | $736 | 143 | - | - | - | - |
$2,467 44,863 kWh |
$736 143 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $486 Cost: $75 |
$486 | 8,829 | - | - | - | - | - | - |
$486 8,829 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $14,556 Cost: $2,500 |
- | - | - | - | $14,556 | 1,401 | - | - |
- - kWh |
- - kW-months/year |
$14,556 1,401 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,123 Cost: $560 |
$2,604 | 47,349 | $519 | 101 | - | - | - | - |
$2,604 47,349 kWh |
$519 101 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $8,208 Cost: $2,500 |
- | - | - | - | $8,208 | 790 | - | - |
- - kWh |
- - kW-months/year |
$8,208 790 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,633 Cost: $4,000 |
$3,303 | 60,060 | $330 | 64 | - | - | - | - |
$3,303 60,060 kWh |
$330 64 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,069 Cost: $4,000 |
$1,858 | 33,779 | $211 | 41 | - | - | - | - |
$1,858 33,779 kWh |
$211 41 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $17,682 Cost: $55,039 |
$16,817 | 305,760 | $865 | 168 | - | - | - | - |
$16,817 305,760 kWh |
$865 168 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $54,887 Cost: $613,200 |
$31,767 | 577,586 | - | - | - | - | $23,120 | - |
$31,767 577,586 kWh |
- - kW-months/year |
- - MMBtu |
$23,120 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $309,796 Cost: $3,462,200 |
$179,356 | 3,261,024 | - | - | - | - | $130,440 | - |
$179,356 3,261,024 kWh |
- - kW-months/year |
- - MMBtu |
$130,440 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $426,075 Cost: $4,144,074 |
$244,295 | 4,441,738 | $2,661 | 517 | $25,559 | 2,460 | $153,560 | - | $244,295 4,441,738 kWh |
$2,661 517 kW-months/year |
$25,559 2,460 MMBtu |
$153,560 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |