Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2025 |
Principal Product | Deli Items |
NAICS | 311612 - Meat Processed from Carcasses |
SIC | 2013 - Sausages And Other Prepared Meats |
Sales | $50,000,000-$100,000,000 |
# of Employees | 95 |
Plant Area (Sq.Ft.) | 55,000 |
Annual Production | 16,000,000 Pounds |
Production Hrs. Annual | 3,120 |
Location (State) | NJ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $408,450 | 4,084,499 | kWh | $0.10 |
Electricity Demand | $143,062 | 16,831 | kW-months/year | $8.50 |
Electricity Fees | $2,604 | - | $ | - |
Natural Gas | $284,760 | 61,016 | MMBtu | $4.67 |
TOTAL ENERGY COSTS | $838,876 | |||
RECOMMENDED SAVINGS* | $120,609 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,457 Cost: $100 |
$4,867 | 48,672 | $1,590 | 187 | - | - | - | - |
$4,867 48,672 kWh |
$1,590 187 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $40,366 Cost: $3,000 |
$33,634 | 336,336 | $6,732 | 792 | - | - | - | - |
$33,634 336,336 kWh |
$6,732 792 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,485 Cost: $7,000 |
$6,485 | 65,848 | - | - | - | - | - | - |
$6,485 65,848 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $2,361 Cost: $3,915 |
$2,114 | 21,137 | $247 | 29 | - | - | - | - |
$2,114 21,137 kWh |
$247 29 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,195 Cost: $4,000 |
$1,872 | 18,720 | $323 | 38 | - | - | - | - |
$1,872 18,720 kWh |
$323 38 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $12,213 Cost: $24,000 |
$9,204 | 92,040 | $3,009 | 354 | - | - | - | - |
$9,204 92,040 kWh |
$3,009 354 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $43,842 Cost: $126,000 |
$23,561 | 235,611 | $306 | 36 | - | - | $19,975 | - |
$23,561 235,611 kWh |
$306 36 kW-months/year |
- - MMBtu |
$19,975 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,177 Cost: $26,000 |
$4,655 | 46,550 | $1,522 | 179 | - | - | - | - |
$4,655 46,550 kWh |
$1,522 179 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $513 Cost: $2,500 |
$(-326) | (-3,259) | $(-76) | (-9) | $915 | 196 | - | - |
$(-326) (-3,259) kWh |
$(-76) (-9) kW-months/year |
$915 196 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $120,609 Cost: $196,515 |
$86,066 | 861,655 | $13,653 | 1,606 | $915 | 196 | $19,975 | - | $86,066 861,655 kWh |
$13,653 1,606 kW-months/year |
$915 196 MMBtu |
$19,975 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||