Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Louisiana Tech
Assessment Year 1984
Principal Product ALUMINUM CASTINGS
NAICS n/a
SIC 3363 - Aluminum Die-castings
Sales $10,000,000-$50,000,000
# of Employees 60
Plant Area (Sq.Ft.) 0
Annual Production 17,500,000 Pounds
Production Hrs. Annual 0
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $102,969 2,097,597 kWh $0.05
Natural Gas $380,583 79,542 MMBtu $4.78
TOTAL ENERGY COSTS $483,552
RECOMMENDED SAVINGS* $98,984 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $87,314
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$6,220
Cost:
$12,200
$6,220 140,973 - - $6,220
140,973
kWh
-
-
MMBtu
02: 2.6122 ADJUST VENTS TO MINIMIZE ENERGY USE Savings:
$10,250
Cost:
$900
- - $10,250 2,145 -
-
kWh
$10,250
2,145
MMBtu
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$14,340
Cost:
-
- - $14,340 3,000 -
-
kWh
$14,340
3,000
MMBtu
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$1,420
Cost:
-
$1,420 - - - $1,420
-
kWh
-
-
MMBtu
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$66,754
Cost:
-
$(-1,600) (-35,170) $68,354 14,300 $(-1,600)
(-35,170)
kWh
$68,354
14,300
MMBtu
TOTAL RECOMMENDED Savings:
$98,984
Cost:
$13,100
$6,040 105,803 $92,944 19,445 $6,040
105,803
kWh
$92,944
19,445
MMBtu
TOTAL IMPLEMENTED Savings:
$87,314
Cost:
$12,200
$4,620 105,803 $82,694 17,300 $4,620
105,803
kWh
$82,694
17,300
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas