Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1985
Principal Product PLASTIC PRODUCTS
NAICS n/a
SIC 3081 - Unsupported Plastics Film & Sheet
Sales $10,000,000-$50,000,000
# of Employees 180
Plant Area (Sq.Ft.) 0
Annual Production 450,000 Pounds
Production Hrs. Annual 6,000
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $285,496 4,621,923 kWh $0.06
Natural Gas $104,511 15,145 MMBtu $6.90
TOTAL ENERGY COSTS $390,007
RECOMMENDED SAVINGS* $26,894 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $22,198
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR Savings:
$11,592
Cost:
$6,000
- - $11,592 1,680 - - -
-
kWh
$11,592
1,680
MMBtu
-
-
$
02: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT Savings:
$9,754
Cost:
$56,300
$37,200 599,941 $(-23,446) (-3,398) $(-4,000) - $37,200
599,941
kWh
$(-23,446)
(-3,398)
MMBtu
$(-4,000)
-
$
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$4,696
Cost:
$13,000
- - $4,696 681 - - -
-
kWh
$4,696
681
MMBtu
-
-
$
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$852
Cost:
$100
$852 17,292 - - - - $852
17,292
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$26,894
Cost:
$75,400
$38,052 617,233 $(-7,158) (-1,037) $(-4,000) - $38,052
617,233
kWh
$(-7,158)
(-1,037)
MMBtu
$(-4,000)
-
$
TOTAL IMPLEMENTED Savings:
$22,198
Cost:
$62,400
$38,052 617,233 $(-11,854) (-1,718) $(-4,000) - $38,052
617,233
kWh
$(-11,854)
(-1,718)
MMBtu
$(-4,000)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes