Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1986
Principal Product PLASTIC SHEET GOODS
NAICS n/a
SIC 3081 - Unsupported Plastics Film & Sheet
Sales $5,000,000-$10,000,000
# of Employees 55
Plant Area (Sq.Ft.) 0
Annual Production 1,250,000 Pounds
Production Hrs. Annual 6,000
Location (State) CT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $261,810 3,337,632 kWh $0.08
Natural Gas $55,039 7,879 MMBtu $6.99
TOTAL ENERGY COSTS $316,849
RECOMMENDED SAVINGS* $90,954 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$8,920
Cost:
$8,800
- - $8,920 1,080 -
-
kWh
$8,920
1,080
MMBtu
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,056
Cost:
$850
- - $1,056 137 -
-
kWh
$1,056
137
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$497
Cost:
$250
$497 6,448 - - $497
6,448
kWh
-
-
MMBtu
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$2,047
Cost:
$190
$2,047 26,084 - - $2,047
26,084
kWh
-
-
MMBtu
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,381
Cost:
$30
$2,381 30,481 - - $2,381
30,481
kWh
-
-
MMBtu
06: 2.7312 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE Savings:
$25,584
Cost:
$22,400
$13,195 168,230 $12,389 1,780 $13,195
168,230
kWh
$12,389
1,780
MMBtu
07: 2.2444 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS Savings:
$10,447
Cost:
$7,700
- - $10,447 1,501 -
-
kWh
$10,447
1,501
MMBtu
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$40,022
Cost:
$35,300
$64,739 825,615 $(-24,717) (-3,521) $64,739
825,615
kWh
$(-24,717)
(-3,521)
MMBtu
TOTAL RECOMMENDED Savings:
$90,954
Cost:
$75,520
$82,859 1,056,858 $8,095 977 $82,859
1,056,858
kWh
$8,095
977
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas