Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1986
Principal Product QUALITY HAND TOOLS
NAICS n/a
SIC 3423 - Hand And Edge Tools, Nec
Sales $1,000,000-$5,000,000
# of Employees 31
Plant Area (Sq.Ft.) 0
Annual Production 400,000 Pounds
Production Hrs. Annual 2,125
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $11,327 104,045 kWh $0.11
Fuel Oil #1 $10,765 1,474 MMBtu $7.30
Fuel Oil #2 $14,137 1,876 MMBtu $7.54
TOTAL ENERGY COSTS $36,229
RECOMMENDED SAVINGS* $14,301 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $9,789
#|Description Savings
Cost
Status Electricity Usage Fuel Oil #1 Fuel Oil #2 Electricity Usage Fuel Oil #1 Fuel Oil #2
$ kWh $ MMBtu $ MMBtu
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$3,191
Cost:
$2,500
$3,191 29,308 - - - - $3,191
29,308
kWh
-
-
MMBtu
-
-
MMBtu
02: 2.7421 REDUCE GLAZED AREAS IN BUILDINGS Savings:
$3,959
Cost:
$8,455
- - $3,959 546 - - -
-
kWh
$3,959
546
MMBtu
-
-
MMBtu
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$377
Cost:
$300
- - $377 52 - - -
-
kWh
$377
52
MMBtu
-
-
MMBtu
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$4,512
Cost:
-
- - - - $4,512 600 -
-
kWh
-
-
MMBtu
$4,512
600
MMBtu
05: 2.2428 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC Savings:
$2,262
Cost:
$7,500
- - $2,262 312 - - -
-
kWh
$2,262
312
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$14,301
Cost:
$18,755
$3,191 29,308 $6,598 910 $4,512 600 $3,191
29,308
kWh
$6,598
910
MMBtu
$4,512
600
MMBtu
TOTAL IMPLEMENTED Savings:
$9,789
Cost:
$18,755
$3,191 29,308 $6,598 910 - - $3,191
29,308
kWh
$6,598
910
MMBtu
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Fuel Oil #1 Fuel Oil #2 Electricity Usage Fuel Oil #1 Fuel Oil #2