Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 1995 |
Principal Product | Miniature die castings |
NAICS | n/a |
SIC | 3369 - Nonferrous Foundries, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 1,360,000 Pounds |
Production Hrs. Annual | 4,250 |
Location (State) | CT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $143,767 | 1,543,083 | kWh | $0.09 |
Natural Gas | $105,632 | 15,119 | MMBtu | $6.99 |
LPG | $2,960 | 592 | MMBtu | $5.00 |
TOTAL ENERGY COSTS | $252,359 | |||
RECOMMENDED SAVINGS* | $49,362 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $43,750 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2514 COVER OPEN TANKS |
Savings: $3,618 Cost: $1,883 |
$1,311 | 14,068 | $2,307 | 330 | - | - | - | - | - | - |
$1,311 14,068 kWh |
$2,307 330 MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $4,067 Cost: $4,632 |
$3,081 | 33,118 | $986 | 141 | - | - | - | - | - | - |
$3,081 33,118 kWh |
$986 141 MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,545 Cost: $2,500 |
- | - | $1,545 | 221 | - | - | - | - | - | - |
- - kWh |
$1,545 221 MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,557 Cost: $1,000 |
$1,557 | 16,706 | - | - | - | - | - | - | - | - |
$1,557 16,706 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $922 Cost: - |
$922 | 28,136 | - | - | - | - | - | - | - | - |
$922 28,136 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $453 Cost: $1,190 |
$453 | 4,982 | - | - | - | - | - | - | - | - |
$453 4,982 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $382 Cost: - |
$382 | 4,103 | - | - | - | - | - | - | - | - |
$382 4,103 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $378 Cost: $255 |
$378 | 4,103 | - | - | - | - | - | - | - | - |
$378 4,103 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5242 RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE |
Savings: $28,487 Cost: $53,330 |
- | - | - | - | - | - | - | - | $28,487 | - |
- - kWh |
- - MMBtu |
- - Tgal |
- - gal |
$28,487 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4112 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER |
Savings: $7,953 Cost: $5,526 |
- | - | - | - | $720 | 480,000 | $1,656 | 2,400 | $5,577 | 312 |
- - kWh |
- - MMBtu |
$720 480,000 Tgal |
$1,656 2,400 gal |
$5,577 312 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $49,362 Cost: $70,316 |
$8,084 | 105,216 | $4,838 | 692 | $720 | 480,000 | $1,656 | 2,400 | $34,064 | 312 | $8,084 105,216 kWh |
$4,838 692 MMBtu |
$720 480,000 Tgal |
$1,656 2,400 gal |
$34,064 312 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $43,750 Cost: $63,184 |
$5,003 | 72,098 | $2,307 | 330 | $720 | 480,000 | $1,656 | 2,400 | $34,064 | 312 | $5,003 72,098 kWh |
$2,307 330 MMBtu |
$720 480,000 Tgal |
$1,656 2,400 gal |
$34,064 312 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) |