Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 1997 |
Principal Product | Plastic Fastners |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 153 |
Plant Area (Sq.Ft.) | 78,872 |
Annual Production | 2,750,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $563,232 | 8,708,382 | kWh | $0.06 |
Electricity Demand | $149,552 | 21,686 | kW-months/year | $6.90 |
Electricity Fees | $443 | - | $ | - |
Natural Gas | $16,711 | 2,840 | MMBtu | $5.88 |
TOTAL ENERGY COSTS | $743,186 | |||
RECOMMENDED SAVINGS* | $143,524 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $104,052 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | By-product Production | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | By-product Production | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.444 INSTALL SYSTEM TO COLLECT SCRAP |
Savings: $62,985 Cost: $16,000 |
- | - | - | - | - | - | - | - | $62,985 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$62,985 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.642 INSTALL SENSORS TO DETECT AND AVOID JAMS |
Savings: $21,374 Cost: $1,500 |
- | - | - | - | - | - | - | - | - | - | - | - | $21,374 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
$21,374 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.624 HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME |
Savings: $2,000 Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | $2,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
$2,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $28,307 Cost: $65,000 |
$41,029 | 634,232 | $1,042 | 151 | $(-13,764) | (-2,369) | - | - | - | - | - | - | - | - |
$41,029 634,232 kWh |
$1,042 151 kW-months/year |
$(-13,764) (-2,369) MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $6,350 Cost: $9,100 |
- | - | - | - | $6,350 | 1,093 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,350 1,093 MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,560 Cost: $4,280 |
$2,560 | 39,566 | - | - | - | - | - | - | - | - | - | - | - | - |
$2,560 39,566 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $3,143 Cost: $900 |
- | - | - | - | $3,143 | 541 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,143 541 MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,757 Cost: $9,700 |
$4,757 | 62,427 | - | - | - | - | - | - | - | - | - | - | - | - |
$4,757 62,427 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $10,200 Cost: - |
- | - | - | - | - | - | - | - | - | - | $10,200 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$10,200 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $1,848 Cost: - |
- | - | - | - | - | - | $1,848 | 288,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,848 288,000 lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $143,524 Cost: $106,480 |
$48,346 | 736,225 | $1,042 | 151 | $(-4,271) | (-735) | $1,848 | 288,000 | $62,985 | - | $10,200 | - | $23,374 | - | $48,346 736,225 kWh |
$1,042 151 kW-months/year |
$(-4,271) (-735) MMBtu |
$1,848 288,000 lb |
$62,985 - $ |
$10,200 - $ |
$23,374 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $104,052 Cost: $85,280 |
$43,589 | 673,798 | $1,042 | 151 | $(-13,764) | (-2,369) | - | - | $62,985 | - | $10,200 | - | - | - | $43,589 673,798 kWh |
$1,042 151 kW-months/year |
$(-13,764) (-2,369) MMBtu |
- - lb |
$62,985 - $ |
$10,200 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | By-product Production | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | By-product Production | Increase in Production |