Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 1998 |
Principal Product | Metal Bellows Seals |
NAICS | n/a |
SIC | 3053 - Gaskets, Packing And Sealing Devices |
Sales | $10,000,000-$50,000,000 |
# of Employees | 185 |
Plant Area (Sq.Ft.) | 55,600 |
Annual Production | 65,000 Pieces |
Production Hrs. Annual | 5,200 |
Location (State) | RI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $153,615 | 2,243,259 | kWh | $0.07 |
Electricity Demand | $43,294 | 8,184 | kW-months/year | $5.29 |
Natural Gas | $32,018 | 4,030 | MMBtu | $7.94 |
TOTAL ENERGY COSTS | $228,927 | |||
RECOMMENDED SAVINGS* | $20,635 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,615 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER |
Savings: $3,022 Cost: $200 |
- | - | - | - | - | - | - | - | - | - | $3,022 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
$3,022 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $3,950 Cost: $1,785 |
$3,950 | 43,669 | - | - | - | - | - | - | - | - | - | - | - | - |
$3,950 43,669 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $1,323 Cost: $187 |
$1,323 | 20,223 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,323 20,223 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $802 Cost: $541 |
$802 | 9,086 | - | - | - | - | - | - | - | - | - | - | - | - |
$802 9,086 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,955 Cost: $2,332 |
- | - | - | - | $1,955 | 260 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,955 260 MMBtu |
- - gal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6112 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME |
Savings: $3,045 Cost: $14,790 |
$1,338 | 16,120 | $571 | 108 | $(-489) | (-65) | $1,625 | 709 | - | - | - | - | - | - |
$1,338 16,120 kWh |
$571 108 kW-months/year |
$(-489) (-65) MMBtu |
$1,625 709 gal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $3,468 Cost: $24,000 |
$2,108 | 22,274 | - | - | - | - | - | - | $1,360 | - | - | - | - | - |
$2,108 22,274 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$1,360 - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $3,070 Cost: $13,540 |
$3,446 | 38,101 | - | - | - | - | - | - | - | - | - | - | $(-376) | - |
$3,446 38,101 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
$(-376) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,635 Cost: $57,375 |
$12,967 | 149,473 | $571 | 108 | $1,466 | 195 | $1,625 | 709 | $1,360 | - | $3,022 | - | $(-376) | - | $12,967 149,473 kWh |
$571 108 kW-months/year |
$1,466 195 MMBtu |
$1,625 709 gal |
$1,360 - $ |
$3,022 - $ |
$(-376) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,615 Cost: $24,928 |
$4,233 | 51,583 | - | - | - | - | - | - | $1,360 | - | $3,022 | - | - | - | $4,233 51,583 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$1,360 - $ |
$3,022 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Water Consumption |