Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 1998 |
Principal Product | Press fabrics |
NAICS | n/a |
SIC | 2299 - Textile Goods, Nec |
Sales | n/a |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 208,000 |
Annual Production | 1,820 Pieces |
Production Hrs. Annual | 8,664 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $555,409 | 8,739,742 | kWh | $0.06 |
Electricity Demand | $187,647 | 21,644 | kW-months/year | $8.67 |
Natural Gas | $126,108 | 31,027 | MMBtu | $4.06 |
TOTAL ENERGY COSTS | $869,164 | |||
RECOMMENDED SAVINGS* | $103,539 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,380 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $25,681 Cost: $7,454 |
- | - | - | - | - | - | - | - | $25,681 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$25,681 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,189 Cost: $9,625 |
$6,189 | 94,666 | - | - | - | - | - | - | - | - |
$6,189 94,666 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,088 Cost: $323 |
$2,088 | 31,946 | - | - | - | - | - | - | - | - |
$2,088 31,946 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,686 Cost: $3,400 |
$1,686 | 25,791 | - | - | - | - | - | - | - | - |
$1,686 25,791 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $925 Cost: $403 |
- | - | - | - | - | - | - | - | $925 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$925 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $65,920 Cost: $385,000 |
$20,099 | 307,444 | $41,333 | 4,956 | $(-2,337) | (-615) | $6,825 | - | - | - |
$20,099 307,444 kWh |
$41,333 4,956 kW-months/year |
$(-2,337) (-615) MMBtu |
$6,825 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,050 Cost: $7,800 |
$1,050 | 16,120 | - | - | - | - | - | - | - | - |
$1,050 16,120 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $103,539 Cost: $414,005 |
$31,112 | 475,967 | $41,333 | 4,956 | $(-2,337) | (-615) | $6,825 | - | $26,606 | - | $31,112 475,967 kWh |
$41,333 4,956 kW-months/year |
$(-2,337) (-615) MMBtu |
$6,825 - $ |
$26,606 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,380 Cost: $11,580 |
$3,774 | 57,737 | - | - | - | - | - | - | $26,606 | - | $3,774 57,737 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$26,606 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Water Consumption |