Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1998
Principal Product Custom glass to metal sealing, soldering and brazing
NAICS n/a
SIC 3679 - Electronic Components, Nec
Sales $5,000,000-$10,000,000
# of Employees 60
Plant Area (Sq.Ft.) 14,280
Annual Production 3,000,000 Pieces
Production Hrs. Annual 2,375
Location (State) NH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $49,079 520,223 kWh $0.09
Electricity Demand $12,254 1,648 kW-months/year $7.44
LPG $8,329 930 MMBtu $8.96
TOTAL ENERGY COSTS $80,245
RECOMMENDED SAVINGS* $16,338 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,784
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Gaseous Waste By-product Production Electricity Usage Electricity Demand LPG Gaseous Waste By-product Production
$ kWh $ kW-months/year $ MMBtu $ lb $ $
01: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN Savings:
$1,280
Cost:
$2,110
$(-81) (-879) $(-34) (-4) - - $1,395 124,693 - - $(-81)
(-879)
kWh
$(-34)
(-4)
kW-months/year
-
-
MMBtu
$1,395
124,693
lb
-
-
$
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$642
Cost:
$30
$437 4,689 $205 24 - - - - - - $437
4,689
kWh
$205
24
kW-months/year
-
-
MMBtu
-
-
lb
-
-
$
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,142
Cost:
$980
$(-54) (-586) $(-17) (-2) $3,213 359 - - - - $(-54)
(-586)
kWh
$(-17)
(-2)
kW-months/year
$3,213
359
MMBtu
-
-
lb
-
-
$
04: 4.424 IMPROVE SPACE COMFORT CONDITIONING Savings:
$5,656
Cost:
$11,874
$(-189) (-2,052) $(-316) (-37) - - - - $6,161 - $(-189)
(-2,052)
kWh
$(-316)
(-37)
kW-months/year
-
-
MMBtu
-
-
lb
$6,161
-
$
05: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION Savings:
$5,618
Cost:
$29,750
$(-3,438) (-37,222) $(-1,527) (-178) - - $10,583 945,997 - - $(-3,438)
(-37,222)
kWh
$(-1,527)
(-178)
kW-months/year
-
-
MMBtu
$10,583
945,997
lb
-
-
$
TOTAL RECOMMENDED Savings:
$16,338
Cost:
$44,744
$(-3,325) (-36,050) $(-1,689) (-197) $3,213 359 $11,978 1,070,690 $6,161 - $(-3,325)
(-36,050)
kWh
$(-1,689)
(-197)
kW-months/year
$3,213
359
MMBtu
$11,978
1,070,690
lb
$6,161
-
$
TOTAL IMPLEMENTED Savings:
$3,784
Cost:
$1,010
$383 4,103 $188 22 $3,213 359 - - - - $383
4,103
kWh
$188
22
kW-months/year
$3,213
359
MMBtu
-
-
lb
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ lb $ $