Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 1999 |
Principal Product | Plastic bottles and labeling |
NAICS | n/a |
SIC | 3085 - Plastics Bottles |
Sales | $10,000,000-$50,000,000 |
# of Employees | 121 |
Plant Area (Sq.Ft.) | 67,000 |
Annual Production | 108,000,000 Pieces |
Production Hrs. Annual | 8,280 |
Location (State) | CT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $281,087 | 4,725,381 | kWh | $0.06 |
Electricity Demand | $74,395 | 7,986 | kW-months/year | $9.32 |
LPG | $7,591 | 938 | MMBtu | $8.09 |
TOTAL ENERGY COSTS | $363,073 | |||
RECOMMENDED SAVINGS* | $41,753 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,317 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | By-product Production | Electricity Usage | Electricity Demand | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.114 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS |
Savings: $18,033 Cost: $25,200 |
$(-3,145) | (-52,462) | $(-662) | (-72) | $21,840 | - |
$(-3,145) (-52,462) kWh |
$(-662) (-72) kW-months/year |
$21,840 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $9,704 Cost: $5,262 |
$8,381 | 140,680 | $1,323 | 144 | - | - |
$8,381 140,680 kWh |
$1,323 144 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,317 Cost: $3,950 |
$3,317 | 55,979 | - | - | - | - |
$3,317 55,979 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,414 Cost: - |
$1,414 | 24,033 | - | - | - | - |
$1,414 24,033 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,135 Cost: - |
$1,135 | 19,050 | - | - | - | - |
$1,135 19,050 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.642 INSTALL SENSORS TO DETECT AND AVOID JAMS |
Savings: $2,000 Cost: $700 |
- | - | - | - | $2,000 | - |
- - kWh |
- - kW-months/year |
$2,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $6,150 Cost: $1,200 |
- | - | - | - | $6,150 | - |
- - kWh |
- - kW-months/year |
$6,150 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $41,753 Cost: $36,312 |
$11,102 | 187,280 | $661 | 72 | $29,990 | - | $11,102 187,280 kWh |
$661 72 kW-months/year |
$29,990 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,317 Cost: $3,950 |
$3,317 | 55,979 | - | - | - | - | $3,317 55,979 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | By-product Production | Electricity Usage | Electricity Demand | By-product Production |