Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2000
Principal Product Venting for fireplaces and boilers
NAICS n/a
SIC 3499 - Fabricated Metal Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 76
Plant Area (Sq.Ft.) 130,000
Annual Production 500,000 Pieces
Production Hrs. Annual 4,420
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $72,966 1,165,592 kWh $0.06
Electricity Demand $26,141 3,571 kW-months/year $7.32
Electricity Fees $8,834 - $ -
Natural Gas $23,312 2,783 MMBtu $8.38
TOTAL ENERGY COSTS $131,253
RECOMMENDED SAVINGS* $13,632 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,469
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$4,970
Cost:
$500
- - - - - - $4,970 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$4,970
-
$
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$3,064
Cost:
$12,000
$526 8,206 - - $2,538 380 - - $526
8,206
kWh
-
-
kW-months/year
$2,538
380
MMBtu
-
-
$
03: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$2,099
Cost:
$4,500
$1,682 26,377 $417 56 - - - - $1,682
26,377
kWh
$417
56
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,495
Cost:
$365
$1,495 23,447 - - - - - - $1,495
23,447
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$1,402
Cost:
$280
$1,402 21,981 - - - - - - $1,402
21,981
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$396
Cost:
$280
$299 4,689 $97 13 - - - - $299
4,689
kWh
$97
13
kW-months/year
-
-
MMBtu
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$206
Cost:
$450
$206 3,224 - - - - - - $206
3,224
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$13,632
Cost:
$18,375
$5,610 87,924 $514 69 $2,538 380 $4,970 - $5,610
87,924
kWh
$514
69
kW-months/year
$2,538
380
MMBtu
$4,970
-
$
TOTAL IMPLEMENTED Savings:
$8,469
Cost:
$1,875
$3,402 53,341 $97 13 - - $4,970 - $3,402
53,341
kWh
$97
13
kW-months/year
-
-
MMBtu
$4,970
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes