IAC logo
IAC Assessment: MA0504
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MA0504
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2002
Principal Product Paper Envelopes
NAICS n/a
SIC 2677 - Envelopes
Sales $50,000,000-$100,000,000
# of Employees 400
Plant Area (Sq.Ft.) 234,000
Annual Production 2,147,483,647 Pieces
Production Hrs. Annual 6,240
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $671,116 12,153,141 kWh $0.06
Electricity Demand $409,386 26,412 kW-months/year $15.50
Electricity Fees $92,722 - $ -
Natural Gas $182,301 15,513 MMBtu $11.75
TOTAL ENERGY COSTS $1,355,525
RECOMMENDED SAVINGS* $214,877 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $76,232
#|Description Savings
Cost
Status Electricity Usage Natural Gas Primary Product Electricity Usage Natural Gas Primary Product
$ kWh $ MMBtu $ $
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$46,658
Cost:
$80,500
$15,758 275,985 - - $30,900 - $15,758
275,985
kWh
-
-
MMBtu
$30,900
-
$
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$117,765
Cost:
$284,800
$75,653 1,324,934 $42,112 (-4,284) - - $75,653
1,324,934
kWh
$42,112
(-4,284)
MMBtu
-
-
$
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$24,477
Cost:
$22,000
- - $24,477 2,490 - - -
-
kWh
$24,477
2,490
MMBtu
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$14,725
Cost:
$46,000
$14,725 257,878 - - - - $14,725
257,878
kWh
-
-
MMBtu
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,155
Cost:
$13,100
$6,155 107,801 - - - - $6,155
107,801
kWh
-
-
MMBtu
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$3,901
Cost:
$7,000
$3,901 68,320 - - - - $3,901
68,320
kWh
-
-
MMBtu
-
-
$
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,196
Cost:
-
$1,196 20,948 - - - - $1,196
20,948
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$214,877
Cost:
$453,400
$117,388 2,055,866 $66,589 (-1,794) $30,900 - $117,388
2,055,866
kWh
$66,589
(-1,794)
MMBtu
$30,900
-
$
TOTAL IMPLEMENTED Savings:
$76,232
Cost:
$109,500
$20,855 365,253 $24,477 2,490 $30,900 - $20,855
365,253
kWh
$24,477
2,490
MMBtu
$30,900
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Primary Product Electricity Usage Natural Gas Primary Product