Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2003
Principal Product candles
NAICS 339999 - All Other Miscellaneous Manufacturing
SIC 3999 - Manufacturing Industries, Nec
Sales $100,000,000-$500,000,000
# of Employees 563
Plant Area (Sq.Ft.) 280,000
Annual Production 45,000,000 Pounds
Production Hrs. Annual 6,120
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $569,689 9,718,560 kWh $0.06
Electricity Demand $118,673 19,603 kW-months/year $6.05
Electricity Fees $91,934 - $ -
Natural Gas $925,048 133,813 MMBtu $6.91
TOTAL ENERGY COSTS $1,705,344
RECOMMENDED SAVINGS* $119,546 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $80,070
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$67,039
Cost:
$7,300
- - - - $67,039 9,121 -
-
kWh
-
-
kW-months/year
$67,039
9,121
MMBtu
02: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER Savings:
$38,956
Cost:
$84,895
$32,437 540,608 $6,519 1,060 - - $32,437
540,608
kWh
$6,519
1,060
kW-months/year
-
-
MMBtu
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$3,833
Cost:
-
$3,833 63,849 - - - - $3,833
63,849
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,606
Cost:
$4,400
$3,606 60,073 - - - - $3,606
60,073
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,385
Cost:
$4,400
$2,385 39,728 - - - - $2,385
39,728
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$1,627
Cost:
$1,845
$1,627 30,474 - - - - $1,627
30,474
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,580
Cost:
-
$1,580 26,316 - - - - $1,580
26,316
kWh
-
-
kW-months/year
-
-
MMBtu
08: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE Savings:
$520
Cost:
-
$520 8,662 - - - - $520
8,662
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$119,546
Cost:
$102,840
$45,988 769,710 $6,519 1,060 $67,039 9,121 $45,988
769,710
kWh
$6,519
1,060
kW-months/year
$67,039
9,121
MMBtu
TOTAL IMPLEMENTED Savings:
$80,070
Cost:
$17,945
$13,031 220,440 - - $67,039 9,121 $13,031
220,440
kWh
-
-
kW-months/year
$67,039
9,121
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas