Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2003 |
Principal Product | Wood furniture |
NAICS | 337122 - Nonupholstered Wood Household Furniture Manufacturing |
SIC | 2511 - Wood Household Furniture |
Sales | $50,000,000-$100,000,000 |
# of Employees | 558 |
Plant Area (Sq.Ft.) | 605,382 |
Annual Production | 11,000 Thousand Feet |
Production Hrs. Annual | 4,200 |
Location (State) | VT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $569,028 | 11,739,000 | kWh | $0.05 |
Electricity Demand | $444,778 | 34,520 | kW-months/year | $12.88 |
Electricity Fees | $5,718 | - | $ | - |
Wood | $466,045 | 456,842 | MMBtu | $1.02 |
TOTAL ENERGY COSTS | $1,485,569 | |||
RECOMMENDED SAVINGS* | $579,216 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,958 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Personnel Changes | Electricity Usage | Electricity Demand | Wood | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3321 USE STEAM PRESSURE REDUCTION TO GENERATE POWER |
Savings: $372,126 Cost: $3,870,145 |
$373,555 | 7,592,577 | $135,139 | 9,814 | $(-34,488) | (-24,939) | $(-102,080) | - |
$373,555 7,592,577 kWh |
$135,139 9,814 kW-months/year |
$(-34,488) (-24,939) MMBtu |
$(-102,080) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS |
Savings: $67,147 Cost: $59,125 |
$(-3,083) | (-62,664) | - | - | $70,230 | 58,525 | - | - |
$(-3,083) (-62,664) kWh |
- - kW-months/year |
$70,230 58,525 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7314 REDUCE VENTILATION AIR |
Savings: $62,192 Cost: - |
- | - | - | - | $63,192 | 35,303 | $(-1,000) | - |
- - kWh |
- - kW-months/year |
$63,192 35,303 MMBtu |
$(-1,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $56,908 Cost: $84,343 |
$40,453 | 822,208 | $16,455 | 1,195 | - | - | - | - |
$40,453 822,208 kWh |
$16,455 1,195 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $5,274 Cost: $6,000 |
$(-2,232) | (-45,360) | $(-165) | (-12) | $7,671 | 4,286 | - | - |
$(-2,232) (-45,360) kWh |
$(-165) (-12) kW-months/year |
$7,671 4,286 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,836 Cost: $11,700 |
- | - | - | - | $3,836 | 2,143 | - | - |
- - kWh |
- - kW-months/year |
$3,836 2,143 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,511 Cost: $5,800 |
$3,511 | 71,636 | - | - | - | - | - | - |
$3,511 71,636 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,521 Cost: $9,300 |
$2,521 | 51,238 | - | - | - | - | - | - |
$2,521 51,238 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,685 Cost: $864 |
- | - | - | - | $1,685 | 1,404 | - | - |
- - kWh |
- - kW-months/year |
$1,685 1,404 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,303 Cost: - |
- | - | $1,303 | 92 | - | - | - | - |
- - kWh |
$1,303 92 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,058 Cost: $1,058 |
$1,058 | 21,504 | - | - | - | - | - | - |
$1,058 21,504 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $1,038 Cost: - |
- | - | - | - | $1,038 | 565 | - | - |
- - kWh |
- - kW-months/year |
$1,038 565 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $617 Cost: - |
$617 | 12,533 | - | - | - | - | - | - |
$617 12,533 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $579,216 Cost: $4,048,335 |
$416,400 | 8,463,672 | $152,732 | 11,089 | $113,164 | 77,287 | $(-103,080) | - | $416,400 8,463,672 kWh |
$152,732 11,089 kW-months/year |
$113,164 77,287 MMBtu |
$(-103,080) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,958 Cost: - |
$617 | 12,533 | $1,303 | 92 | $1,038 | 565 | - | - | $617 12,533 kWh |
$1,303 92 kW-months/year |
$1,038 565 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Personnel Changes | Electricity Usage | Electricity Demand | Wood | Personnel Changes |