Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2004
Principal Product Porous plug wrap and tobacco sheet
NAICS 322121 - Paper (except Newsprint) Mills
SIC 2621 - Paper Mills
Sales $50,000,000-$100,000,000
# of Employees 110
Plant Area (Sq.Ft.) 114,000
Annual Production 11,000 Tons
Production Hrs. Annual 8,640
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $996,080 19,211,220 kWh $0.05
Electricity Demand $172,555 32,233 kW-months/year $5.35
Electricity Fees $3,025 - $ -
Fuel Oil #6 $1,032,472 193,500 MMBtu $5.34
TOTAL ENERGY COSTS $2,204,132
RECOMMENDED SAVINGS* $378,650 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $44,254
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Fuel Oil #6 Electricity Usage Electricity Demand Fuel Oil #6
$ kWh $ kW-months/year $ MMBtu
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$239,059
Cost:
$699,000
$(-6,348) (-135,350) $(-1,358) (-251) $246,765 44,785 $(-6,348)
(-135,350)
kWh
$(-1,358)
(-251)
kW-months/year
$246,765
44,785
MMBtu
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$70,580
Cost:
$123,500
$(-1,857) (-39,600) $(-460) (-85) $72,897 13,230 $(-1,857)
(-39,600)
kWh
$(-460)
(-85)
kW-months/year
$72,897
13,230
MMBtu
03: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$36,905
Cost:
$15,475
$31,809 678,200 $5,096 942 - - $31,809
678,200
kWh
$5,096
942
kW-months/year
-
-
MMBtu
04: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$16,513
Cost:
$4,078
- - - - $16,513 2,997 -
-
kWh
-
-
kW-months/year
$16,513
2,997
MMBtu
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$7,349
Cost:
$11,346
$6,332 135,000 $1,017 188 - - $6,332
135,000
kWh
$1,017
188
kW-months/year
-
-
MMBtu
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,861
Cost:
$14,400
$5,914 126,100 $947 175 - - $5,914
126,100
kWh
$947
175
kW-months/year
-
-
MMBtu
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,383
Cost:
$333
- - - - $1,383 251 -
-
kWh
-
-
kW-months/year
$1,383
251
MMBtu
TOTAL RECOMMENDED Savings:
$378,650
Cost:
$868,132
$35,850 764,350 $5,242 969 $337,558 61,263 $35,850
764,350
kWh
$5,242
969
kW-months/year
$337,558
61,263
MMBtu
TOTAL IMPLEMENTED Savings:
$44,254
Cost:
$26,821
$38,141 813,200 $6,113 1,130 - - $38,141
813,200
kWh
$6,113
1,130
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Fuel Oil #6 Electricity Usage Electricity Demand Fuel Oil #6