Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2004 |
Principal Product | Paper products |
NAICS | 322121 - Paper (except Newsprint) Mills |
SIC | 2621 - Paper Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 104,500 |
Annual Production | 30,600 Tons |
Production Hrs. Annual | 8,640 |
Location (State) | NH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,134,119 | 16,596,400 | kWh | $0.07 |
Electricity Demand | $315,733 | 31,858 | kW-months/year | $9.91 |
Electricity Fees | $5,376 | - | $ | - |
Fuel Oil #6 | $1,142,152 | 175,792 | MMBtu | $6.50 |
TOTAL ENERGY COSTS | $2,597,380 | |||
RECOMMENDED SAVINGS* | $469,096 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $301,681 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #6 | Personnel Changes | Electricity Usage | Electricity Demand | Fuel Oil #6 | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $148,951 Cost: $35,885 |
- | - | - | - | $150,951 | 22,941 | $(-2,000) | - |
- - kWh |
- - kW-months/year |
$150,951 22,941 MMBtu |
$(-2,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3414 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT |
Savings: $113,441 Cost: $191,180 |
$227,585 | 2,891,809 | $8,822 | 1,273 | $(-111,399) | (-16,930) | $(-11,567) | - |
$227,585 2,891,809 kWh |
$8,822 1,273 kW-months/year |
$(-111,399) (-16,930) MMBtu |
$(-11,567) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2163 USE MINIMUM STEAM OPERATING PRESSURE |
Savings: $75,183 Cost: $1,350 |
- | - | - | - | $75,183 | 11,426 | - | - |
- - kWh |
- - kW-months/year |
$75,183 11,426 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $69,926 Cost: $70,000 |
- | - | - | - | $69,926 | 10,627 | - | - |
- - kWh |
- - kW-months/year |
$69,926 10,627 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $33,400 Cost: $20,000 |
- | - | - | - | $33,400 | 5,079 | - | - |
- - kWh |
- - kW-months/year |
$33,400 5,079 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $22,306 Cost: $16,750 |
- | - | - | - | $22,306 | 3,390 | - | - |
- - kWh |
- - kW-months/year |
$22,306 3,390 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $5,889 Cost: $3,076 |
- | - | - | - | $5,889 | 895 | - | - |
- - kWh |
- - kW-months/year |
$5,889 895 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $469,096 Cost: $338,241 |
$227,585 | 2,891,809 | $8,822 | 1,273 | $246,256 | 37,428 | $(-13,567) | - | $227,585 2,891,809 kWh |
$8,822 1,273 kW-months/year |
$246,256 37,428 MMBtu |
$(-13,567) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $301,681 Cost: $250,141 |
$227,585 | 2,891,809 | $8,822 | 1,273 | $78,841 | 11,985 | $(-13,567) | - | $227,585 2,891,809 kWh |
$8,822 1,273 kW-months/year |
$78,841 11,985 MMBtu |
$(-13,567) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #6 | Personnel Changes | Electricity Usage | Electricity Demand | Fuel Oil #6 | Personnel Changes |