Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2011 |
Principal Product | clothes |
NAICS | 314999 - All Other Miscellaneous Textile Product Mills |
SIC | 2299 - Textile Goods, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 102 |
Plant Area (Sq.Ft.) | 6,000 |
Annual Production | 624,000 Pieces |
Production Hrs. Annual | 3,744 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $66,672 | 675,280 | kWh | $0.10 |
Electricity Demand | $46,558 | 2,082 | kW-months/year | $22.36 |
Electricity Fees | $7,816 | - | $ | - |
Natural Gas | $222,932 | 17,011 | MMBtu | $13.11 |
TOTAL ENERGY COSTS | $343,978 | |||
RECOMMENDED SAVINGS* | $45,039 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,520 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $36,635 Cost: $200,000 |
$55,881 | 564,452 | $20,125 | 900 | $(-29,864) | (-2,299) | $(-9,507) | - |
$55,881 564,452 kWh |
$20,125 900 kW-months/year |
$(-29,864) (-2,299) MMBtu |
$(-9,507) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $4,780 Cost: $3,550 |
- | - | - | - | $4,780 | 368 | - | - |
- - kWh |
- - kW-months/year |
$4,780 368 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2691 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS |
Savings: $1,556 Cost: $15,000 |
$1,556 | 15,727 | - | - | - | - | - | - |
$1,556 15,727 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,328 Cost: $2,220 |
$1,328 | 13,418 | - | - | - | - | - | - |
$1,328 13,418 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $740 Cost: $200 |
$740 | 7,465 | - | - | - | - | - | - |
$740 7,465 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $45,039 Cost: $220,970 |
$59,505 | 601,062 | $20,125 | 900 | $(-25,084) | (-1,931) | $(-9,507) | - | $59,505 601,062 kWh |
$20,125 900 kW-months/year |
$(-25,084) (-1,931) MMBtu |
$(-9,507) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,520 Cost: $3,750 |
$740 | 7,465 | - | - | $4,780 | 368 | - | - | $740 7,465 kWh |
- - kW-months/year |
$4,780 368 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |