Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2012 |
Principal Product | Printed wireboard |
NAICS | 332993 - Ammunition (except Small Arms) Manufacturing |
SIC | 3483 - Ammunition, Exc. For Small Arms, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 700 |
Plant Area (Sq.Ft.) | 724,338 |
Annual Production | 1,000,000 Pieces |
Production Hrs. Annual | 4,250 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,910,332 | 21,582,040 | kWh | $0.09 |
Electricity Demand | $401,244 | 51,199 | kW-months/year | $7.84 |
Natural Gas | $586,319 | 109,242 | MMBtu | $5.37 |
TOTAL ENERGY COSTS | $2,897,895 | |||
RECOMMENDED SAVINGS* | $209,519 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $160,963 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $85,000 Cost: $250,000 |
$38,576 | 433,440 | - | - | $46,424 | 8,645 |
$38,576 433,440 kWh |
- - kW-months/year |
$46,424 8,645 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $32,036 Cost: $4,000 |
$32,036 | 359,952 | - | - | - | - |
$32,036 359,952 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $19,784 Cost: $5,000 |
$19,784 | 222,289 | - | - | - | - |
$19,784 222,289 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $13,757 Cost: $8,000 |
$7,565 | 84,996 | - | - | $6,192 | 1,153 |
$7,565 84,996 kWh |
- - kW-months/year |
$6,192 1,153 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $10,785 Cost: $3,000 |
$10,785 | 121,180 | - | - | - | - |
$10,785 121,180 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $7,905 Cost: $12,000 |
- | - | - | - | $7,905 | 1,472 |
- - kWh |
- - kW-months/year |
$7,905 1,472 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $7,677 Cost: $9,750 |
$7,677 | 86,261 | - | - | - | - |
$7,677 86,261 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,958 Cost: $9,500 |
$6,958 | 78,175 | - | - | - | - |
$6,958 78,175 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $5,818 Cost: $900 |
$4,706 | 52,871 | - | - | $1,112 | 207 |
$4,706 52,871 kWh |
- - kW-months/year |
$1,112 207 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $5,139 Cost: $5,200 |
$3,822 | 42,942 | $1,317 | 168 | - | - |
$3,822 42,942 kWh |
$1,317 168 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,144 Cost: $1,000 |
$4,144 | 46,559 | - | - | - | - |
$4,144 46,559 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $2,245 Cost: $1,500 |
$2,245 | 25,228 | - | - | - | - |
$2,245 25,228 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,032 Cost: $700 |
$2,032 | 22,830 | - | - | - | - |
$2,032 22,830 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,657 Cost: $6,000 |
$1,657 | 18,620 | - | - | - | - |
$1,657 18,620 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,579 Cost: $2,300 |
- | - | - | - | $1,579 | 294 |
- - kWh |
- - kW-months/year |
$1,579 294 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,244 Cost: $1,000 |
$1,244 | 13,977 | - | - | - | - |
$1,244 13,977 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $1,042 Cost: $500 |
- | - | - | - | $1,042 | 194 |
- - kWh |
- - kW-months/year |
$1,042 194 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
18: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $717 Cost: $200 |
$717 | 8,059 | - | - | - | - |
$717 8,059 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $209,519 Cost: $320,550 |
$143,948 | 1,617,379 | $1,317 | 168 | $64,254 | 11,965 | $143,948 1,617,379 kWh |
$1,317 168 kW-months/year |
$64,254 11,965 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $160,963 Cost: $289,050 |
$103,297 | 1,160,632 | $1,317 | 168 | $56,349 | 10,493 | $103,297 1,160,632 kWh |
$1,317 168 kW-months/year |
$56,349 10,493 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |