Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2012 |
Principal Product | Newspaper printing |
NAICS | 511110 - Newspaper Publishers |
SIC | 2711 - Newspapers |
Sales | $50,000,000-$100,000,000 |
# of Employees | 158 |
Plant Area (Sq.Ft.) | 145,000 |
Annual Production | 25,000 Tons |
Production Hrs. Annual | 3,650 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $492,823 | 5,716,800 | kWh | $0.09 |
Electricity Demand | $186,900 | 28,665 | kW-months/year | $6.52 |
Electricity Fees | $1,755 | - | $ | - |
Natural Gas | $37,555 | 3,845 | MMBtu | $9.77 |
TOTAL ENERGY COSTS | $719,033 | |||
RECOMMENDED SAVINGS* | $68,944 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,694 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $29,785 Cost: $80,000 |
$22,571 | 261,809 | - | - | $7,214 | 798 |
$22,571 261,809 kWh |
- - kW-months/year |
$7,214 798 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $12,823 Cost: $24,111 |
- | - | $12,823 | 1,967 | - | - |
- - kWh |
$12,823 1,967 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7314 REDUCE VENTILATION AIR |
Savings: $3,642 Cost: $6,000 |
$894 | 10,368 | - | - | $2,748 | 304 |
$894 10,368 kWh |
- - kW-months/year |
$2,748 304 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $9,553 Cost: $47,000 |
$9,553 | 110,807 | - | - | - | - |
$9,553 110,807 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,855 Cost: $11,200 |
$7,855 | 91,109 | - | - | - | - |
$7,855 91,109 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $5,286 Cost: $500 |
$1,326 | 15,377 | - | - | $3,960 | 438 |
$1,326 15,377 kWh |
- - kW-months/year |
$3,960 438 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $68,944 Cost: $168,811 |
$42,199 | 489,470 | $12,823 | 1,967 | $13,922 | 1,540 | $42,199 489,470 kWh |
$12,823 1,967 kW-months/year |
$13,922 1,540 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,694 Cost: $58,700 |
$18,734 | 217,293 | - | - | $3,960 | 438 | $18,734 217,293 kWh |
- - kW-months/year |
$3,960 438 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |