Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2014
Principal Product Jet engine components
NAICS 336412 - Aircraft Engine and Engine Parts Manufacturing
SIC 3724 - Aircraft Engines And Engine Parts
Sales $100,000,000-$500,000,000
# of Employees 1,291
Plant Area (Sq.Ft.) 876,960
Annual Production 1,000 Pieces
Production Hrs. Annual 8,400
Location (State) ME
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $3,412,448 44,844,161 kWh $0.08
Electricity Demand $87,909 84,897 kW-months/year $1.04
Electricity Fees $28,010 - $ -
Natural Gas $903,036 118,795 MMBtu $7.60
TOTAL ENERGY COSTS $4,431,403
RECOMMENDED SAVINGS* $74,882 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $63,835
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$23,304
Cost:
$90,000
$23,304 297,642 - - $23,304
297,642
kWh
-
-
MMBtu
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$20,745
Cost:
$110,500
$20,745 264,944 - - $20,745
264,944
kWh
-
-
MMBtu
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$16,628
Cost:
$5,000
$8,413 107,451 $8,215 1,091 $8,413
107,451
kWh
$8,215
1,091
MMBtu
04: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$11,047
Cost:
$32,000
- - $11,047 1,467 -
-
kWh
$11,047
1,467
MMBtu
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,158
Cost:
$1,250
$3,158 40,331 - - $3,158
40,331
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$74,882
Cost:
$238,750
$55,620 710,368 $19,262 2,558 $55,620
710,368
kWh
$19,262
2,558
MMBtu
TOTAL IMPLEMENTED Savings:
$63,835
Cost:
$206,750
$55,620 710,368 $8,215 1,091 $55,620
710,368
kWh
$8,215
1,091
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas