IAC logo
IAC Assessment: MA0749
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MA0749
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2015
Principal Product Lighting fixtures
NAICS 335122 - Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing
SIC 3646 - Commercial Lighting Fixtures
Sales $5,000,000-$10,000,000
# of Employees 385
Plant Area (Sq.Ft.) 315,000
Annual Production 1,800,000 Pieces
Production Hrs. Annual 2,522
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $655,278 5,759,778 kWh $0.11
Electricity Demand $118,309 21,552 kW-months/year $5.49
Electricity Fees $(-1,123) - $ -
Natural Gas $631,714 47,704 MMBtu $13.24
TOTAL ENERGY COSTS $1,404,178
RECOMMENDED SAVINGS* $114,521 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $90,318
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7314 REDUCE VENTILATION AIR Savings:
$30,757
Cost:
$20,400
$21,583 189,659 - - $9,174 703 $21,583
189,659
kWh
-
-
kW-months/year
$9,174
703
MMBtu
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$24,207
Cost:
$1,000
$24,207 212,716 - - - - $24,207
212,716
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$17,980
Cost:
$3,330
$17,980 157,997 - - - - $17,980
157,997
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$10,366
Cost:
$25,300
- - $10,366 2,644 - - -
-
kWh
$10,366
2,644
kW-months/year
-
-
MMBtu
05: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$8,523
Cost:
$1,000
$1,659 14,575 - - $6,864 526 $1,659
14,575
kWh
-
-
kW-months/year
$6,864
526
MMBtu
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,856
Cost:
$24,500
$6,856 60,242 - - - - $6,856
60,242
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,067
Cost:
$3,000
$6,067 53,315 - - - - $6,067
53,315
kWh
-
-
kW-months/year
-
-
MMBtu
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,495
Cost:
$500
$2,495 21,927 - - - - $2,495
21,927
kWh
-
-
kW-months/year
-
-
MMBtu
09: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$3,372
Cost:
$1,000
$3,372 29,635 - - - - $3,372
29,635
kWh
-
-
kW-months/year
-
-
MMBtu
10: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$1,592
Cost:
$500
- - - - $1,592 122 -
-
kWh
-
-
kW-months/year
$1,592
122
MMBtu
11: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,227
Cost:
$1,013
- - - - $1,227 94 -
-
kWh
-
-
kW-months/year
$1,227
94
MMBtu
12: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,079
Cost:
$100
$400 3,518 - - $679 52 $400
3,518
kWh
-
-
kW-months/year
$679
52
MMBtu
TOTAL RECOMMENDED Savings:
$114,521
Cost:
$81,643
$84,619 743,584 $10,366 2,644 $19,536 1,497 $84,619
743,584
kWh
$10,366
2,644
kW-months/year
$19,536
1,497
MMBtu
TOTAL IMPLEMENTED Savings:
$90,318
Cost:
$53,330
$80,465 707,082 - - $9,853 755 $80,465
707,082
kWh
-
-
kW-months/year
$9,853
755
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas