IAC logo
IAC Assessment: MA0769
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MA0769
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2017
Principal Product Powdered metal products
NAICS 332117 - Powder Metallurgy Part Manufacturing
SIC 3499 - Fabricated Metal Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 225
Plant Area (Sq.Ft.) 88,000
Annual Production 4,200,000 Pounds
Production Hrs. Annual 8,568
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,329,652 12,250,500 kWh $0.11
Electricity Demand $86,859 22,158 kW-months/year $3.92
Electricity Fees $2,400 - $ -
Natural Gas $52,752 4,901 MMBtu $10.76
TOTAL ENERGY COSTS $1,471,663
RECOMMENDED SAVINGS* $146,303 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $90,487
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$90,487
Cost:
$39,330
$90,487 830,155 - - - - $90,487
830,155
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$30,931
Cost:
$24,720
$45,678 419,067 $4,481 1,143 $(-19,228) (-1,787) $45,678
419,067
kWh
$4,481
1,143
kW-months/year
$(-19,228)
(-1,787)
MMBtu
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$12,391
Cost:
$11,273
$12,391 113,638 - - - - $12,391
113,638
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.3311 REPLACE DC EQUIPMENT WITH AC EQUIPMENT Savings:
$8,620
Cost:
$57,572
$8,620 79,080 - - - - $8,620
79,080
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,874
Cost:
$7,200
$3,874 35,539 - - - - $3,874
35,539
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$146,303
Cost:
$140,095
$161,050 1,477,479 $4,481 1,143 $(-19,228) (-1,787) $161,050
1,477,479
kWh
$4,481
1,143
kW-months/year
$(-19,228)
(-1,787)
MMBtu
TOTAL IMPLEMENTED Savings:
$90,487
Cost:
$39,330
$90,487 830,155 - - - - $90,487
830,155
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas