IAC logo
IAC Assessment: MA0771
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MA0771
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2017
Principal Product Treated drinking water
NAICS 221310 - Water Supply and Irrigation Systems
SIC 4941 - Water Supply
Sales $1,000,000-$5,000,000
# of Employees 4
Plant Area (Sq.Ft.) 13,000
Annual Production 1,359,540 Thousand Gallons
Production Hrs. Annual 3,094
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $250,248 2,245,080 kWh $0.11
Electricity Demand $87,404 3,633 kW-months/year $24.06
Electricity Fees $(-436) - $ -
Natural Gas $12,054 1,703 MMBtu $7.08
TOTAL ENERGY COSTS $349,270
RECOMMENDED SAVINGS* $22,401 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $13,668
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM Savings:
$13,141
Cost:
$1,000
$11,907 107,266 $4,114 171 - - $(-2,880) - $11,907
107,266
kWh
$4,114
171
kW-months/year
-
-
MMBtu
$(-2,880)
-
$
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$8,733
Cost:
$3,480
- - $8,733 363 - - - - -
-
kWh
$8,733
363
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$527
Cost:
$2,116
$(-161) (-1,453) $(-48) (-2) $736 104 - - $(-161)
(-1,453)
kWh
$(-48)
(-2)
kW-months/year
$736
104
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$22,401
Cost:
$6,596
$11,746 105,813 $12,799 532 $736 104 $(-2,880) - $11,746
105,813
kWh
$12,799
532
kW-months/year
$736
104
MMBtu
$(-2,880)
-
$
TOTAL IMPLEMENTED Savings:
$13,668
Cost:
$3,116
$11,746 105,813 $4,066 169 $736 104 $(-2,880) - $11,746
105,813
kWh
$4,066
169
kW-months/year
$736
104
MMBtu
$(-2,880)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes