Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2017 |
Principal Product | Treated drinking water |
NAICS | 221310 - Water Supply and Irrigation Systems |
SIC | 4941 - Water Supply |
Sales | $1,000,000-$5,000,000 |
# of Employees | 4 |
Plant Area (Sq.Ft.) | 13,000 |
Annual Production | 1,359,540 Thousand Gallons |
Production Hrs. Annual | 3,094 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $250,248 | 2,245,080 | kWh | $0.11 |
Electricity Demand | $87,404 | 3,633 | kW-months/year | $24.06 |
Electricity Fees | $(-436) | - | $ | - |
Natural Gas | $12,054 | 1,703 | MMBtu | $7.08 |
TOTAL ENERGY COSTS | $349,270 | |||
RECOMMENDED SAVINGS* | $22,401 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,668 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $13,141 Cost: $1,000 |
$11,907 | 107,266 | $4,114 | 171 | - | - | $(-2,880) | - |
$11,907 107,266 kWh |
$4,114 171 kW-months/year |
- - MMBtu |
$(-2,880) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $8,733 Cost: $3,480 |
- | - | $8,733 | 363 | - | - | - | - |
- - kWh |
$8,733 363 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $527 Cost: $2,116 |
$(-161) | (-1,453) | $(-48) | (-2) | $736 | 104 | - | - |
$(-161) (-1,453) kWh |
$(-48) (-2) kW-months/year |
$736 104 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $22,401 Cost: $6,596 |
$11,746 | 105,813 | $12,799 | 532 | $736 | 104 | $(-2,880) | - | $11,746 105,813 kWh |
$12,799 532 kW-months/year |
$736 104 MMBtu |
$(-2,880) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,668 Cost: $3,116 |
$11,746 | 105,813 | $4,066 | 169 | $736 | 104 | $(-2,880) | - | $11,746 105,813 kWh |
$4,066 169 kW-months/year |
$736 104 MMBtu |
$(-2,880) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |