Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2022 |
Principal Product | Specialty paper |
NAICS | 322121 - Paper (except Newsprint) Mills |
SIC | 2621 - Paper Mills |
Sales | $100,000,000-$500,000,000 |
# of Employees | 57 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 22,782 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,705,591 | 20,936,000 | kWh | $0.08 |
Electricity Demand | $268,202 | 33,525 | kW-months/year | $8.00 |
Electricity Fees | $207 | - | $ | - |
Fuel Oil #2 | $52,871 | 3,774 | MMBtu | $14.01 |
Wood | $740,756 | 349,213 | MMBtu | $2.12 |
TOTAL ENERGY COSTS | $2,767,627 | |||
RECOMMENDED SAVINGS* | $674,814 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Wood | Personnel Changes | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $443,207 Cost: $3,043,367 |
- | - | - | - | $53,012 | 24,994 | - | - | - | - | $390,195 | - |
- - kWh |
- - kW-months/year |
$53,012 24,994 MMBtu |
- - $ |
- - $ |
$390,195 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2444 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS |
Savings: $127,245 Cost: $144,842 |
- | - | - | - | $127,245 | 59,993 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$127,245 59,993 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $64,198 Cost: $280,195 |
$32,813 | 405,097 | $3,984 | 498 | - | - | - | - | $27,401 | - | - | - |
$32,813 405,097 kWh |
$3,984 498 kW-months/year |
- - MMBtu |
- - $ |
$27,401 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $29,256 Cost: $3,515 |
- | - | - | - | $35,756 | 16,858 | $(-6,500) | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$35,756 16,858 MMBtu |
$(-6,500) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $10,386 Cost: $12,000 |
$8,578 | 105,900 | $1,808 | 226 | - | - | - | - | - | - | - | - |
$8,578 105,900 kWh |
$1,808 226 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $522 Cost: $910 |
- | - | - | - | $522 | 246 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$522 246 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $674,814 Cost: $3,484,829 |
$41,391 | 510,997 | $5,792 | 724 | $216,535 | 102,091 | $(-6,500) | - | $27,401 | - | $390,195 | - | $41,391 510,997 kWh |
$5,792 724 kW-months/year |
$216,535 102,091 MMBtu |
$(-6,500) - $ |
$27,401 - $ |
$390,195 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Wood | Personnel Changes | Administrative Changes | Primary Product |