Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2023 |
Principal Product | Water |
NAICS | 221310 - Water Supply and Irrigation Systems |
SIC | 4941 - Water Supply |
Sales | $5,000,000-$10,000,000 |
# of Employees | 3 |
Plant Area (Sq.Ft.) | 10,000 |
Annual Production | 1,460,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $206,478 | 1,822,724 | kWh | $0.11 |
Electricity Demand | $70,203 | 3,800 | kW-months/year | $18.47 |
Electricity Fees | $9,120 | - | $ | - |
LPG | $2,917 | 204 | MMBtu | $14.30 |
TOTAL ENERGY COSTS | $288,718 | |||
RECOMMENDED SAVINGS* | $880,034 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $786,360 Cost: $8,384,740 |
$429,193 | 3,798,169 | $33,829 | 1,831 | $323,338 | - | - | - |
$429,193 3,798,169 kWh |
$33,829 1,831 kW-months/year |
$323,338 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7273 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM |
Savings: $53,317 Cost: $27,882 |
$(-5,464) | (-48,355) | $(-1,219) | (-66) | - | - | $60,000 | - |
$(-5,464) (-48,355) kWh |
$(-1,219) (-66) kW-months/year |
- - $ |
$60,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $22,535 Cost: $8,016 |
$18,415 | 162,965 | $4,120 | 223 | - | - | - | - |
$18,415 162,965 kWh |
$4,120 223 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $9,331 Cost: $2,100 |
$5,562 | 49,224 | $3,769 | 204 | - | - | - | - |
$5,562 49,224 kWh |
$3,769 204 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $8,491 Cost: $10,020 |
$5,165 | 45,708 | $3,326 | 180 | - | - | - | - |
$5,165 45,708 kWh |
$3,326 180 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $880,034 Cost: $8,432,758 |
$452,871 | 4,007,711 | $43,825 | 2,372 | $323,338 | - | $60,000 | - | $452,871 4,007,711 kWh |
$43,825 2,372 kW-months/year |
$323,338 - $ |
$60,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost |