Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2023 |
Principal Product | Beer |
NAICS | 312120 - Breweries |
SIC | 2082 - Malt Beverages |
Sales | $50,000,000-$100,000,000 |
# of Employees | 19 |
Plant Area (Sq.Ft.) | 229,194 |
Annual Production | 372 Thousand Gallons |
Production Hrs. Annual | 3,500 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $359,827 | 1,386,560 | kWh | $0.26 |
Electricity Demand | $175,571 | 5,812 | kW-months/year | $30.21 |
Electricity Fees | $47,827 | - | $ | - |
Natural Gas | $134,624 | 9,763 | MMBtu | $13.79 |
TOTAL ENERGY COSTS | $753,834 | |||
RECOMMENDED SAVINGS* | $233,943 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $166,002 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $135,448 Cost: $385,041 |
$100,089 | 384,956 | $14,775 | 489 | - | - | - | - | - | - | $20,584 | - |
$100,089 384,956 kWh |
$14,775 489 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$20,584 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $43,839 Cost: $169,678 |
$63,950 | 193,433 | - | - | - | - | $(-14,953) | (-1,116) | $(-5,158) | - | - | - |
$63,950 193,433 kWh |
- - kW-months/year |
- - $ |
$(-14,953) (-1,116) MMBtu |
$(-5,158) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $28,576 Cost: $1,000 |
- | - | - | - | $28,576 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$28,576 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $18,230 Cost: $3,215 |
$13,034 | 50,130 | $5,196 | 172 | - | - | - | - | - | - | - | - |
$13,034 50,130 kWh |
$5,196 172 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $5,872 Cost: $20,925 |
- | - | - | - | - | - | $5,872 | 452 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$5,872 452 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,544 Cost: $5,977 |
$1,333 | 5,125 | $211 | 7 | - | - | - | - | - | - | - | - |
$1,333 5,125 kWh |
$211 7 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2626 AVOID FROST FORMATION ON EVAPORATORS |
Savings: $434 Cost: $216 |
$374 | 1,438 | $60 | 2 | - | - | - | - | - | - | - | - |
$374 1,438 kWh |
$60 2 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $233,943 Cost: $586,052 |
$178,780 | 635,082 | $20,242 | 670 | $28,576 | - | $(-9,081) | (-664) | $(-5,158) | - | $20,584 | - | $178,780 635,082 kWh |
$20,242 670 kW-months/year |
$28,576 - $ |
$(-9,081) (-664) MMBtu |
$(-5,158) - $ |
$20,584 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $166,002 Cost: $392,234 |
$101,796 | 391,519 | $15,046 | 498 | $28,576 | - | - | - | - | - | $20,584 | - | $101,796 391,519 kWh |
$15,046 498 kW-months/year |
$28,576 - $ |
- - MMBtu |
- - $ |
$20,584 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost |