IAC logo
IAC Assessment: MI0008
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0008
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2001
Principal Product Heating equipment
NAICS n/a
SIC 3433 - Heating Equipment, Except Electric
Sales $10,000,000-$50,000,000
# of Employees 124
Plant Area (Sq.Ft.) 105,000
Annual Production 15,000 Pieces
Production Hrs. Annual 6,045
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $53,908 991,813 kWh $0.05
Electricity Demand $25,000 2,064 kW-months/year $12.11
TOTAL ENERGY COSTS $78,908
RECOMMENDED SAVINGS* $253,518 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Primary Raw Material Primary Product Electricity Usage Administrative Changes Primary Raw Material Primary Product
$ kWh $ $ $ $ $ $
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$3,994
Cost:
$125
$3,994 49,921 - - - - - - $3,994
49,921
kWh
-
-
$
-
-
$
-
-
$
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$12,780
Cost:
$87
$12,780 159,749 - - - - - - $12,780
159,749
kWh
-
-
$
-
-
$
-
-
$
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,272
Cost:
$5
$1,272 15,897 - - - - - - $1,272
15,897
kWh
-
-
$
-
-
$
-
-
$
04: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL Savings:
$22,533
Cost:
$40
- - - - $22,533 - - - -
-
kWh
-
-
$
$22,533
-
$
-
-
$
05: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES Savings:
$28,850
Cost:
$400
- - $28,850 - - - - - -
-
kWh
$28,850
-
$
-
-
$
-
-
$
06: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS Savings:
$78,789
Cost:
$44,200
- - - - - - $78,789 - -
-
kWh
-
-
$
-
-
$
$78,789
-
$
07: 4.323 OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS Savings:
$105,300
Cost:
$1,212
- - - - $105,300 - - - -
-
kWh
-
-
$
$105,300
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$253,518
Cost:
$46,069
$18,046 225,567 $28,850 - $127,833 - $78,789 - $18,046
225,567
kWh
$28,850
-
$
$127,833
-
$
$78,789
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
$
-
-
$
-
-
$
Savings
Cost
$ kWh $ $ $ $ $ $
Electricity Usage Administrative Changes Primary Raw Material Primary Product Electricity Usage Administrative Changes Primary Raw Material Primary Product