Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2001
Principal Product Aircraft generator repair
NAICS n/a
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $10,000,000-$50,000,000
# of Employees 65
Plant Area (Sq.Ft.) 38,400
Annual Production 8,000 Pieces
Production Hrs. Annual 2,210
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $72,125 1,057,805 kWh $0.07
Electricity Demand $19,902 2,451 kW-months/year $8.12
TOTAL ENERGY COSTS $92,027
RECOMMENDED SAVINGS* $619,918 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $609,256
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Primary Product Electricity Usage Electricity Demand Primary Product
$ kWh $ kW-months/year $ $
01: 4.1220 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS Savings:
$59,040
Cost:
$5,100
- - - - $59,040 - -
-
kWh
-
-
kW-months/year
$59,040
-
$
02: 4.1220 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS Savings:
$73,364
Cost:
$5,100
- - - - $73,364 - -
-
kWh
-
-
kW-months/year
$73,364
-
$
03: 4.1220 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS Savings:
$18,892
Cost:
$5,100
- - - - $18,892 - -
-
kWh
-
-
kW-months/year
$18,892
-
$
04: 4.3220 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL Savings:
$114,007
Cost:
$5,100
- - - - $114,007 - -
-
kWh
-
-
kW-months/year
$114,007
-
$
05: 4.1220 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS Savings:
$316,160
Cost:
$164,000
- - - - $316,160 - -
-
kWh
-
-
kW-months/year
$316,160
-
$
06: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$27,793
Cost:
$19
$7,418 109,093 $20,375 2,509 - - $7,418
109,093
kWh
$20,375
2,509
kW-months/year
-
-
$
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$10,662
Cost:
$760
$10,662 95,118 - - - - $10,662
95,118
kWh
-
-
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$619,918
Cost:
$185,179
$18,080 204,211 $20,375 2,509 $581,463 - $18,080
204,211
kWh
$20,375
2,509
kW-months/year
$581,463
-
$
TOTAL IMPLEMENTED Savings:
$609,256
Cost:
$184,419
$7,418 109,093 $20,375 2,509 $581,463 - $7,418
109,093
kWh
$20,375
2,509
kW-months/year
$581,463
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Primary Product Electricity Usage Electricity Demand Primary Product