Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2001 |
Principal Product | Soft drink bottling |
NAICS | n/a |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $5,000,000-$10,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 124,392 |
Annual Production | 184,800,000 Pieces |
Production Hrs. Annual | 4,862 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $129,636 | 4,449,474 | kWh | $0.03 |
Electricity Demand | $39,157 | 10,743 | kW-months/year | $3.64 |
LPG | $2,520 | 2,635 | MMBtu | $0.96 |
TOTAL ENERGY COSTS | $171,313 | |||
RECOMMENDED SAVINGS* | $165,430 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,257 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Primary Product | Electricity Usage | Electricity Demand | LPG | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.522 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE |
Savings: $96,925 Cost: $990 |
$1,885 | 36,967 | - | - | - | - | $95,040 | - |
$1,885 36,967 kWh |
- - kW-months/year |
- - MMBtu |
$95,040 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $45,630 Cost: - |
- | - | - | - | $630 | 659 | $45,000 | - |
- - kWh |
- - kW-months/year |
$630 659 MMBtu |
$45,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.454 MODIFY STARTUP/SHUTDOWN TIMES |
Savings: $9,086 Cost: $867 |
- | - | $9,086 | 168 | - | - | - | - |
- - kWh |
$9,086 168 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $5,618 Cost: $5,000 |
$5,618 | 76,908 | - | - | - | - | - | - |
$5,618 76,908 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $661 Cost: $5 |
$661 | 12,964 | - | - | - | - | - | - |
$661 12,964 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $5,056 Cost: $20 |
$5,056 | 99,136 | - | - | - | - | - | - |
$5,056 99,136 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,454 Cost: $80 |
$2,454 | 33,592 | - | - | - | - | - | - |
$2,454 33,592 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $165,430 Cost: $6,962 |
$15,674 | 259,567 | $9,086 | 168 | $630 | 659 | $140,040 | - | $15,674 259,567 kWh |
$9,086 168 kW-months/year |
$630 659 MMBtu |
$140,040 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,257 Cost: $972 |
$8,171 | 145,692 | $9,086 | 168 | - | - | - | - | $8,171 145,692 kWh |
$9,086 168 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Primary Product | Electricity Usage | Electricity Demand | LPG | Primary Product |