Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2002 |
Principal Product | Crushed limestone,gravel,sand |
NAICS | n/a |
SIC | 3272 - Concrete Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 135 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 12,000,000 Tons |
Production Hrs. Annual | 4,836 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $523,006 | 38,881,698 | kWh | $0.01 |
Electricity Demand | $1,951,227 | 188,592 | kW-months/year | $10.35 |
TOTAL ENERGY COSTS | $2,474,233 | |||
RECOMMENDED SAVINGS* | $366,146 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $72,800 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Product | Electricity Usage | Electricity Demand | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $132,680 Cost: $46,380 |
- | - | $132,680 | 47,899 | - | - |
- - kWh |
$132,680 47,899 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $72,800 Cost: $35,000 |
- | - | - | - | $72,800 | - |
- - kWh |
- - kW-months/year |
$72,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $60,800 Cost: $5,460 |
- | - | - | - | $60,800 | - |
- - kWh |
- - kW-months/year |
$60,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $60,800 Cost: $925 |
- | - | - | - | $60,800 | - |
- - kWh |
- - kW-months/year |
$60,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $39,066 Cost: $2,938 |
$34,826 | 696,510 | $4,240 | 1,531 | - | - |
$34,826 696,510 kWh |
$4,240 1,531 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $366,146 Cost: $90,703 |
$34,826 | 696,510 | $136,920 | 49,430 | $194,400 | - | $34,826 696,510 kWh |
$136,920 49,430 kW-months/year |
$194,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $72,800 Cost: $35,000 |
- | - | - | - | $72,800 | - | - - kWh |
- - kW-months/year |
$72,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Product | Electricity Usage | Electricity Demand | Primary Product |