Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2003 |
Principal Product | Polypropylene sidings |
NAICS | 326121 - Unlaminated Plastics Profile Shape Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 114,000 |
Annual Production | 6,500,000 Pieces |
Production Hrs. Annual | 5,460 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $518,662 | 11,142,000 | kWh | $0.05 |
Electricity Demand | $167,007 | 20,000 | kW-months/year | $8.35 |
TOTAL ENERGY COSTS | $691,922 | |||
RECOMMENDED SAVINGS* | $54,639 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $41,106 |
#|Description |
Savings Cost |
Status | Electricity Usage | Water Disposal | Administrative Changes | Primary Product | Electricity Usage | Water Disposal | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4155 METER WASTE WATER |
Savings: $1,881 Cost: $1,454 |
- | - | $1,881 | - | - | - | - | - |
- - kWh |
$1,881 - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $35,000 Cost: $7,660 |
- | - | - | - | - | - | $35,000 | - |
- - kWh |
- - Tgal |
- - $ |
$35,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $4,563 Cost: $654 |
$4,563 | 65,181 | - | - | - | - | - | - |
$4,563 65,181 kWh |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,089 Cost: $885 |
$7,089 | 97,373 | - | - | - | - | - | - |
$7,089 97,373 kWh |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,991 Cost: $169 |
$1,991 | 28,443 | - | - | - | - | - | - |
$1,991 28,443 kWh |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $4,115 Cost: - |
- | - | - | - | $4,115 | - | - | - |
- - kWh |
- - Tgal |
$4,115 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $54,639 Cost: $10,822 |
$13,643 | 190,997 | $1,881 | - | $4,115 | - | $35,000 | - | $13,643 190,997 kWh |
$1,881 - Tgal |
$4,115 - $ |
$35,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $41,106 Cost: $7,829 |
$1,991 | 28,443 | - | - | $4,115 | - | $35,000 | - | $1,991 28,443 kWh |
- - Tgal |
$4,115 - $ |
$35,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Water Disposal | Administrative Changes | Primary Product | Electricity Usage | Water Disposal | Administrative Changes | Primary Product |