IAC logo
IAC Assessment: MI0058
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0058
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2003
Principal Product Pharmaceutical (Tablets & Capsules)
NAICS 325412 - Pharmaceutical Preparation Manufacturing
SIC 2834 - Pharmaceutical Preparations
Sales $50,000,000-$100,000,000
# of Employees 76
Plant Area (Sq.Ft.) 60,868
Annual Production 375,000,000 Pieces
Production Hrs. Annual 8,736
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $243,911 5,191,815 kWh $0.05
Electricity Demand $119,516 3,393 kW-months/year $35.22
Natural Gas $95,228 15,585 MMBtu $6.11
TOTAL ENERGY COSTS $708,655
RECOMMENDED SAVINGS* $291,303 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $265,426
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Disposal Administrative Changes Electricity Usage Natural Gas Water Disposal Administrative Changes
$ kWh $ MMBtu $ Tgal $ $
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$11,548
Cost:
$2,000
- - - - - - $11,548 - -
-
kWh
-
-
MMBtu
-
-
Tgal
$11,548
-
$
02: 2.2113 REPAIR OR REPLACE STEAM TRAPS Savings:
$1,906
Cost:
$696
- - $1,906 312 - - - - -
-
kWh
$1,906
312
MMBtu
-
-
Tgal
-
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,543
Cost:
$223
$1,543 22,043 - - - - - - $1,543
22,043
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
04: 3.4155 METER WASTE WATER Savings:
$12,786
Cost:
$1,950
- - - - $12,786 - - - -
-
kWh
-
-
MMBtu
$12,786
-
Tgal
-
-
$
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$250,000
Cost:
$43,000
- - - - $250,000 - - - -
-
kWh
-
-
MMBtu
$250,000
-
Tgal
-
-
$
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$13,520
Cost:
$400,000
$13,520 193,143 - - - - - - $13,520
193,143
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$291,303
Cost:
$447,869
$15,063 215,186 $1,906 312 $262,786 - $11,548 - $15,063
215,186
kWh
$1,906
312
MMBtu
$262,786
-
Tgal
$11,548
-
$
TOTAL IMPLEMENTED Savings:
$265,426
Cost:
$443,696
$13,520 193,143 $1,906 312 $250,000 - - - $13,520
193,143
kWh
$1,906
312
MMBtu
$250,000
-
Tgal
-
-
$
Savings
Cost
$ kWh $ MMBtu $ Tgal $ $
Electricity Usage Natural Gas Water Disposal Administrative Changes Electricity Usage Natural Gas Water Disposal Administrative Changes