Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2004 |
Principal Product | Citrus fruit packaging |
NAICS | 311411 - Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2030 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 102,150 |
Annual Production | 15,000,000 Pieces |
Production Hrs. Annual | 2,500 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $69,851 | 2,122,080 | kWh | $0.03 |
Electricity Demand | $47,156 | 5,786 | kW-months/year | $8.15 |
Electricity Fees | $12,453 | - | $ | - |
LPG | $41,784 | 3,751 | MMBtu | $11.14 |
TOTAL ENERGY COSTS | $171,244 | |||
RECOMMENDED SAVINGS* | $221,288 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $168,750 |
#|Description |
Savings Cost |
Status | Electricity Usage | LPG | Administrative Changes | Primary Product | Electricity Usage | LPG | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $20,512 Cost: $600 |
- | - | - | - | $20,512 | - | - | - |
- - kWh |
- - MMBtu |
$20,512 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $12,574 Cost: $2,300 |
$12,574 | 245,103 | - | - | - | - | - | - |
$12,574 245,103 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $3,925 Cost: - |
$3,925 | 80,417 | - | - | - | - | - | - |
$3,925 80,417 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE |
Savings: $6,702 Cost: $3,693 |
$6,702 | 141,047 | - | - | - | - | - | - |
$6,702 141,047 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $168,750 Cost: $6,904 |
- | - | - | - | - | - | $168,750 | - |
- - kWh |
- - MMBtu |
- - $ |
$168,750 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,151 Cost: $2,661 |
$2,151 | 45,276 | - | - | - | - | - | - |
$2,151 45,276 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,680 Cost: $2,670 |
$1,680 | 35,353 | - | - | - | - | - | - |
$1,680 35,353 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY |
Savings: $2,345 Cost: $239 |
- | - | $2,345 | 178 | - | - | - | - |
- - kWh |
$2,345 178 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $2,649 Cost: $15,260 |
$2,649 | 55,769 | - | - | - | - | - | - |
$2,649 55,769 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $221,288 Cost: $34,327 |
$29,681 | 602,965 | $2,345 | 178 | $20,512 | - | $168,750 | - | $29,681 602,965 kWh |
$2,345 178 MMBtu |
$20,512 - $ |
$168,750 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $168,750 Cost: $6,904 |
- | - | - | - | - | - | $168,750 | - | - - kWh |
- - MMBtu |
- - $ |
$168,750 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | LPG | Administrative Changes | Primary Product | Electricity Usage | LPG | Administrative Changes | Primary Product |