IAC logo
IAC Assessment: MI0086
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0086
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2004
Principal Product Aircraft Engine Parts Remanufacturing
NAICS 336412 - Aircraft Engine and Engine Parts Manufacturing
SIC 3724 - Aircraft Engines And Engine Parts
Sales $10,000,000-$50,000,000
# of Employees 53
Plant Area (Sq.Ft.) 45,480
Annual Production 200 Pieces
Production Hrs. Annual 4,250
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $85,926 1,648,320 kWh $0.05
Electricity Demand $75,691 9,491 kW-months/year $7.98
Electricity Fees $20,357 - $ -
TOTAL ENERGY COSTS $187,725
RECOMMENDED SAVINGS* $121,472 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $121,352
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Primary Product Electricity Usage Administrative Changes Primary Product
$ kWh $ $ $ $
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$21,915
Cost:
$2,300
$21,915 369,941 - - - - $21,915
369,941
kWh
-
-
$
-
-
$
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$3,200
Cost:
$2,300
$3,200 66,936 - - - - $3,200
66,936
kWh
-
-
$
-
-
$
03: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$792
Cost:
$80
$792 15,836 - - - - $792
15,836
kWh
-
-
$
-
-
$
04: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$90,000
Cost:
$50,000
- - - - $90,000 - -
-
kWh
-
-
$
$90,000
-
$
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER Savings:
$120
Cost:
$15
- - $120 - - - -
-
kWh
$120
-
$
-
-
$
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,490
Cost:
$610
$1,490 29,281 - - - - $1,490
29,281
kWh
-
-
$
-
-
$
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$340
Cost:
$386
$340 6,460 - - - - $340
6,460
kWh
-
-
$
-
-
$
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,615
Cost:
$490
$3,615 68,627 - - - - $3,615
68,627
kWh
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$121,472
Cost:
$56,181
$31,352 557,081 $120 - $90,000 - $31,352
557,081
kWh
$120
-
$
$90,000
-
$
TOTAL IMPLEMENTED Savings:
$121,352
Cost:
$56,166
$31,352 557,081 - - $90,000 - $31,352
557,081
kWh
-
-
$
$90,000
-
$
Savings
Cost
$ kWh $ $ $ $
Electricity Usage Administrative Changes Primary Product Electricity Usage Administrative Changes Primary Product