Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2004 |
Principal Product | Electrical Cables |
NAICS | 335931 - Current-Carrying Wiring Device Manufacturing |
SIC | 3643 - Current-carrying Wiring Devices |
Sales | $10,000,000-$50,000,000 |
# of Employees | 69 |
Plant Area (Sq.Ft.) | 67,000 |
Annual Production | 200,000 Pieces |
Production Hrs. Annual | 4,000 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $90,563 | 1,801,440 | kWh | $0.05 |
Electricity Demand | $42,914 | 5,332 | kW-months/year | $8.05 |
Electricity Fees | $11,260 | - | $ | - |
LPG | $4,920 | 284 | MMBtu | $17.32 |
TOTAL ENERGY COSTS | $149,657 | |||
RECOMMENDED SAVINGS* | $125,336 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,088 |
#|Description |
Savings Cost |
Status | Electricity Usage | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Personnel Changes | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $2,620 Cost: - |
- | - | - | - | $2,620 | - | - | - |
- - kWh |
- - $ |
$2,620 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $44,199 Cost: - |
$44,199 | 744,500 | - | - | - | - | - | - |
$44,199 744,500 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $553 Cost: - |
$553 | 10,479 | - | - | - | - | - | - |
$553 10,479 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,800 Cost: - |
$1,800 | 34,133 | - | - | - | - | - | - |
$1,800 34,133 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $28,521 Cost: - |
- | - | - | - | - | - | $28,521 | - |
- - kWh |
- - $ |
- - $ |
$28,521 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,994 Cost: - |
$3,474 | 65,887 | $(-480) | - | - | - | - | - |
$3,474 65,887 kWh |
$(-480) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM |
Savings: $8,755 Cost: $510 |
$8,755 | 83,211 | - | - | - | - | - | - |
$8,755 83,211 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.622 INSTALL ROTATING CAROUSELS TO REDUCE SET-UP TIMES |
Savings: $23,333 Cost: $21,000 |
- | - | - | - | - | - | $23,333 | - |
- - kWh |
- - $ |
- - $ |
$23,333 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $12,561 Cost: - |
$12,561 | 238,764 | - | - | - | - | - | - |
$12,561 238,764 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $125,336 Cost: $21,510 |
$71,342 | 1,176,974 | $(-480) | - | $2,620 | - | $51,854 | - | $71,342 1,176,974 kWh |
$(-480) - $ |
$2,620 - $ |
$51,854 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,088 Cost: $21,510 |
$8,755 | 83,211 | - | - | - | - | $23,333 | - | $8,755 83,211 kWh |
- - $ |
- - $ |
$23,333 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Personnel Changes | Administrative Changes | Primary Product |