Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2005 |
Principal Product | Glass Manufacturer |
NAICS | 327215 - Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231 - Products Of Purchased Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 73,000 |
Annual Production | 3,750,000 Thousand Feet |
Production Hrs. Annual | 6,000 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $255,833 | 5,059,200 | kWh | $0.05 |
Electricity Demand | $120,239 | 14,601 | kW-months/year | $8.23 |
Electricity Fees | $70,900 | - | $ | - |
TOTAL ENERGY COSTS | $446,972 | |||
RECOMMENDED SAVINGS* | $437,677 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $118,440 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Administrative Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $319,237 Cost: $91,320 |
$7,699 | 155,893 | - | - | - | - | $311,538 | - |
$7,699 155,893 kWh |
- - kW-months/year |
- - $ |
$311,538 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $89,581 Cost: $90 |
- | - | - | - | $89,581 | - | - | - |
- - kWh |
- - kW-months/year |
$89,581 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $19,066 Cost: $8,226 |
$14,718 | 297,310 | $4,348 | 528 | - | - | - | - |
$14,718 297,310 kWh |
$4,348 528 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $6,289 Cost: $600 |
- | - | - | - | $6,289 | - | - | - |
- - kWh |
- - kW-months/year |
$6,289 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,504 Cost: $1,393 |
$3,504 | 61,361 | - | - | - | - | - | - |
$3,504 61,361 kWh |
- - kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $437,677 Cost: $101,629 |
$25,921 | 514,564 | $4,348 | 528 | $95,870 | - | $311,538 | - | $25,921 514,564 kWh |
$4,348 528 kW-months/year |
$95,870 - $ |
$311,538 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $118,440 Cost: $10,309 |
$18,222 | 358,671 | $4,348 | 528 | $95,870 | - | - | - | $18,222 358,671 kWh |
$4,348 528 kW-months/year |
$95,870 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Administrative Changes | Increase in Production |